Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Factor IX Activity and Human Inhibitor

Factor IX Activity and Human Inhibitor: Quest Diagnostics test 17845

Quest Diagnostics test 17845, CPT 85250, 85335. Specimen: Two - 2 mL frozen plasma specimens collected in 3.2% sodium citrate (light blue-top) tubes.

Factor IX Activity and Human Inhibitor is Quest Diagnostics test code 17845, billed with CPT 85250, 85335. Specimen: Two - 2 mL frozen plasma specimens collected in 3.2% sodium citrate (light blue-top) tubes. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Labcorp, Michigan Medicine Laboratories (MLabs), OHSU Laboratory Services, ARUP Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code17845
CPT85250, 85335
LOINC—
SpecimenTwo - 2 mL frozen plasma specimens collected in 3.2% sodium citrate (light blue-top) tubes
Minimum volume1 mL (x2)
ContainerPlastic screw-cap vial (x2)
Storage / transportFrozen

Also known as: APTT; Bethesda Titer; Factor IX Inhibitor Panel

Methodology

Clot Based Assay • Photometric Clot Detection

Collection instructions

Platelet poor plasma: Centrifuge light blue-top tube for 15 minutes at approximately 1500 x g within 60 minutes of collection. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Centrifuge a second time and transfer platelet-poor plasma into a new plastic vial. Plasma must be free of platelets (<10,000/mcL). Freeze immediately and ship on dry ice. Do not thaw.

Stability

TemperaturePeriod
Room temperatureUnacceptable
RefrigeratedUnacceptable
Frozen14 days

Notices

Not offered in Quest Diagnostics Nichols Institute (IFD) – San Juan Capistrano. Please provide Service area information to confirm Test Code for the lab that services your account or to find available tests you can order.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 85250, 85335

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation