Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › OHSU Laboratory Services › Factor IX Activity w/Reflex to Inhibitor

Factor IX Activity w/Reflex to Inhibitor: OHSU Laboratory Services test LAB101690

OHSU Laboratory Services test LAB101690, CPT 85250, 85335. Specimen: 3.2% 2 to 2.7 mL blood in a LIGHT BLUE top tube, 3.2% sodium citrate.. Turnaround: Activity: 4 Hours..

Factor IX Activity w/Reflex to Inhibitor is OHSU Laboratory Services test code LAB101690, billed with CPT 85250, 85335. Specimen: 3.2% 2 to 2.7 mL blood in a LIGHT BLUE top tube, 3.2% sodium citrate.. Turnaround time: Activity: 4 Hours.. Performing laboratory: OHSU Laboratory Services, CLIA 38D0676694 (Portland, OR). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Labcorp, Michigan Medicine Laboratories (MLabs), ARUP Laboratories.
LaboratoryOHSU Laboratory Services
CLIA number38D0676694
Test codeLAB101690
CPT85250 x 1; 85335 x 1 (if reflexed)
LOINC—
Specimen3.2% 2 to 2.7 mL blood in a LIGHT BLUE top tube, 3.2% sodium citrate. 3.2% sodium citrate tubes are acceptable when they are filled to the line on the manufacturers label. Tubes must be full (see comments below). For referral testing, submit 2 x 1.0 mL platelet poor citrated plasma. Sodium citrate specimens must be processed and frozen within 1 hours of specimen collection. OHSU Clinics must cab specimens to the Core Lab, Hatfield Research Center (HRC), Room 9D05 if processing is delayed or not possible on site. A phone call is helpful to alert the lab at 503-494-5764. Detailed instructions are under Hemostasis & Thrombosis section (Opens in a new window) .
Turnaround timeActivity: 4 Hours. Urgent: 60 Minutes

Also known as: Factor 9; Inhibitor; FIX

Test includes

If factor activity level is less than 40%, an inhibitor test will be performed.

Reference range

Reference Range: 65% to 150% Inhibitor: Less than 0.6 BU

Special instructions

Draw volume is critical due to the liquid anticoagulant. Allow tubes to fill by vacuum. Tubes with rubber stopper: fill to line on label. Tubes with plastic (Hemogard) cap: the fill level is above the top of the label. Syringe: do not remove the vacutainer stopper. Insert the needle through the stopper and allow the tube to fill by vacuum. Do not overfill the vacutainer. Pediatric tubes have no vacuum. Remove the cap and add blood to the 1.3 mL mark. Do not overfill. Avoid warfarin (Coumadin) therapy for two weeks and heparin therapy for 2 days prior to the test. Inhibitors to factor IX arise in about 3% of persons with severe hemophilia B, which is less common that the incidence of inhibitors to factor VIII in persons with severe hemophilia A. In both types of hemophilia, most inhibitors arise early in life, after only a few injections of the missing clotting factor. Inhibitors to factor IX are sometimes more dangerous than those to factor VIII. The reaction between factor VIII and its inhibitor-antibody does not cause symptoms. The reaction between factor IX and its inhibitor-antibody may cause severe allergic reactions which can be life-threatening (so-called "anaphylactic reactions"). Such reactions may occur with the very first infusion of factor IX after an inhibitor has developed - before anyone is aware that an inhibitor has arisen. All inhibitors in hemophilia B do not cause allergic reactions on exposure to more factor IX. Development of an inhibitor to factor IX can be predicted, at least in part, by determining the kind of factor IX gene mutation the baby has. Methodology: clotting, Bethesda assay.

Units

Factors: %; Inhibitors: Bethesda Units (BU)

Section

Core Lab

Performed

Activity: 24 hours, 7 days a week. Inhibitor: batched twice per week.

Pediatric specimen

Sodium citrate tubes are acceptable when they are filled to the line on the manufacturers label. One 2.7 mL correctly filled in an adult size LIGHT BLUE top tube, or two correctly filled 1.3 mL pediatric BLUE top tubes, 3.2% sodium citrate. A single 1.3 mL pediatric tube may be sent but will only allow for factor activity testing; the inhibitor, if indicated, may not be performed due to insufficient plasma volume. For pediatric patients requiring multiple coagulation tests, please call 503-494-7383 regarding draw volumes.

View this test on OHSU Laboratory Services's website → · Last checked 2026-11-29

Other tests billed with CPT 85250, 85335

Search the National Lab Test Directory · All OHSU Laboratory Services tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation