Coagulation Factor 8 Inhibitor Assay: Michigan Medicine Laboratories (MLabs) test INH8
Michigan Medicine Laboratories (MLabs) test INH8, CPT 85335. Specimen: 2 full 2.7mL tubes or 2mL of plasma (two 1mL aliquots). Turnaround: 8 hours.
Coagulation Factor 8 Inhibitor Assay is Michigan Medicine Laboratories (MLabs) test code INH8, billed with CPT 85335. Specimen: 2 full 2.7mL tubes or 2mL of plasma (two 1mL aliquots). Turnaround time: 8 hours. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA
23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories, OHSU Laboratory Services, Labcorp.
Test codeINH8
CPT85335
LOINC—
Specimen2 full 2.7mL tubes or 2mL of plasma (two 1mL aliquots)
Volume2 full 2.7mL tubes or 2mL of plasma (two 1mL aliquots)
Turnaround time8 hours
Storage / transportRoom temperature for whole blood or frozen aliquot of citrated plasma.
Also known as: Bethesda Inhibitor; Factor 8 Inhibitor; Factor VIII Inhibitor Assay; Factor VIII:C Inhibitor Assay; Inhibitor Assay VIII
Use
Evaluation of increased bleeding problems in patients with hemophilia or abrupt-onset bleeding distress in postpartum women, patient with collagen vascular disorders, or elderly individuals. Assay is suitable for both treated and untreated patients.
Collection instructions
MLabs recommends performing or ordering a Factor VIII Assay activity level prior to ordering the Factor VIII Inhibitor Assay because the Inhibitor Assay will not be performed if the Factor VIII level is greater than 50%. A Factor VIII level is included in the order for the Factor VIII Inhibitor Assay. Collect specimen in a blue top (citrate 3.2%) tube. Mix by inversion. Specimen should arrive at lab within 3 hours of collection; transport at room temperature. Alternatively, centrifuge, aliquot plasma into a plastic vial, and freeze the specimen within 4 hours of collection. Transport frozen specimen on dry ice. Collection of the blood through lines that have been previously flushed with heparin should be avoided. If the blood must be drawn through a VAD (vascular access device), the line should be flushed with 5 mL of saline and the first 5 mL of blood or six dead space volumes of the VAD discarded.
Reference range
The Factor VIII inhibitor level in a normal individual is less than 0.5 Bethesda unit. Critical value: greater than 0.5 Bethesda unit (if no prior inhibitor present).
Limitations
Patients receiving Hemlibra will need to be tested using chromogenic methods. Please notify the special coagulation laboratory at 936-5316 when a patient is receiving Hemlibra.
Section
Coagulation
Performed
Thursday, starting at 8am. Contact Special Coagulation lab if assay is needed on an urgent basis.
Contraindications
Test is not indicated if Factor VIII level is greater than 50%,if patient is receiving anticoagulation therapy, or if the patient is receiving factor replacement therapy.
NY State approved
No
Performing Laboratory
Clinical Core Laboratory
View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29
Other tests billed with CPT 85335
- ADAMTS13 Evaluation
Cleveland Clinic LaboratoriesTest code ADM13CPT 85335, 85390, 85397Platelet-poor plasmaTAT 2 - 4 days
- ADAMTS13 Inhibitor
ARUP LaboratoriesTest code 3000228CPT 85335Light Blue (Sodium Citrate). Refer to Specimen Handling at aruplab.com for hemosTAT 1-3 days
- ADAMTS13 Inhibitor Assay
Cleveland Clinic LaboratoriesTest code ADM13ICPT 85335PlasmaTAT 2 - 4 days
- ADAMTS13 Reflex Panel
ARUP LaboratoriesTest code 3000239CPT 83520, 85335, 85397Light blue (sodium citrate). Refer to Specimen Handling at aruplab.com for hemosTAT 1-3 days
- Bethesda Inhibitor
Cleveland Clinic LaboratoriesTest code BETHDACPT 85210, 85220, 85230, 85240, 85250, 85260, 85270, 85335PlasmaTAT 1 - 3 days
- Coagulation Factor 9 Inhibitor Assay
Michigan Medicine Laboratories (MLabs)Test code INH9CPT 853352 full 2.7mL tubes or 2mL of plasma (two 1mL aliquots)TAT 4 hours
- Coagulation Specific Factor Inhibitor Assay
Michigan Medicine Laboratories (MLabs)Test code INH2, INH5, INH7, INH10, INH11, INH12CPT 853352 full 2.7mL tubes or 2mL of plasma (two 1 mL aliquots)TAT 3 hours
- Factor IX Activity w/Reflex to Inhibitor
OHSU Laboratory ServicesTest code LAB101690CPT 85250, 853353.2% 2 to 2.7 mL blood in a LIGHT BLUE top tube, 3.2% sodium citrate.TAT Activity: 4 Hours.
- Factor IX Activity with Reflex to Bethesda Quantitative, Factor IX
ARUP LaboratoriesTest code 0030032CPT 85250, 85335Lt. blue (sodium citrate). Refer to Specimen Handling at aruplab.com for hemostaTAT 1-3 days
- Factor V (5) w/Reflex to Inhibitor
OHSU Laboratory ServicesTest code LAB101688CPT 85220, 85335Three full 2.7 mL LIGHT BLUE top tubes, 3.2% sodium citrate. Specimens must be pTAT 1 to 3 days
- Factor VIII Activity w/Reflex to Inhibitor
OHSU Laboratory ServicesTest code LAB101689CPT 85240, 853352 to 2.7 mL blood in a LIGHT BLUE top tub, 3.2% sodium citrate.TAT Activity: 4 Hours
- Factor VIII Activity with Reflex to Bethesda Quantitative, Factor VIII
ARUP LaboratoriesTest code 0030026CPT 85240, 85335Lt. blue (sodium citrate). Refer to Specimen Handling at aruplab.com for hemostaTAT 1-3 days
- Factor VIII Chromogenic Bethesda Profile, for Patients on Emicizumab
LabcorpTest code 504722CPT 85240, 85335Citrated plasma, frozenTAT 5 - 10 days
- Factor XI (11) w/Reflex to Inhibitor
OHSU Laboratory ServicesTest code LAB101691CPT 85270, 85335ThreeTAT 1 to 3 days
- Prolonged Clot Time Reflexive Profile
ARUP LaboratoriesTest code 3006383CPT 85210, 85220, 85230, 85240, 85245, 85246, 85250, 85260, 85270, 85280, 85335, 85379, 85384, 85385, 85390, 85397, 85520, 85525, 85598, 85610, 85611, 85613, 85670, 85730, 85732At least five light blue (sodium citrate) tubes. Refer to Specimen Handling at aTAT 2-10 days
Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code.
Submit your lab's test menu → Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation