Coagulation Specific Factor Inhibitor Assay: Michigan Medicine Laboratories (MLabs) test INH2, INH5, INH7, INH10, INH11, INH12
Michigan Medicine Laboratories (MLabs) test INH2, INH5, INH7, INH10, INH11, INH12, CPT 85335. Specimen: 2 full 2.7mL tubes or 2mL of plasma (two 1 mL aliquots). Turnaround: 3 hours.
Also known as: Bethesda Inhibitor; Coagulation Factor II Inhibitor Assay; Factor II Inhibitor Assay; Specific Factor Inhibitor Assay; Inhibitor Assay II:C; Inhibitor Assay V:C; Inhibitor Assay VII:C; Inhibitor Assay X:C; Inhibitor Assay XI:C; Inhibitor Assay XII:C; Coagulation Factor V Inhibitor Assay; Factor V Inhibitor Assay; Factor VII Inhibitor Assay; Coagulation Factor X Inhibitor Assay; Factor X Inhibitor Assay; Inhibitor Assay II, V, VII, X, XI, or XII; Coagulation Factor XI Inhibitor Assay; Factor XI Inhibitor Assay; Coagulation Factor XII Inhibitor Assay; Coagulation Factor VII Inhibitor Assay; Factor XII Inhibitor Assay; Factor 7 Inhibitor Assay; Factor 2 Inhibitor Assay; Factor 5 Inhibitor Assay; Factor 10 Inhibitor Assay; Factor 11 Inhibitor Assay; Factor 12 Inhibitor Assay
Use
Detection of inhibitors directed against specific coagulation factors.
Collection instructions
The specific factor assay activity level is included in this order.If the factor activity level is >50%, the inhibitor level will not be performed. Collect specimen in two blue top (citrate 3.2%) tubes. Mix by inversion. Specimen should arrive at lab within 3 hours of collection; transport at room temperature. Alternatively, centrifuge, aliquot plasma from each blue top tube into separate plastic vials, and freeze the specimen within 4 hours of collection. Transport frozen specimen on dry ice. Collection of the blood through lines that have been previously flushed with heparin should be avoided. If the blood must be drawn through a VAD (vascular access device), the line should be flushed with 5 mL of saline and the first 5 mL of blood or six dead space volumes of the VAD discarded.
Reference range
Normal individuals have <0.5 Bethesda units. Critical value is >0.5 Bethesda units if no prior inhibitor has been detected.
Section
Coagulation
Performed
Thursday, starting at 8am.
Contraindications
Test is not indicated if Factor level is greater than 50%, if the patient is receiving anticoagulation therapy, or if the patient is receiving factor replacement therapy.
NY State approved
No
Performing Laboratory
Clinical Core Laboratory
View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29
Other tests billed with CPT 85335
- ADAMTS13 Evaluation
- ADAMTS13 Inhibitor
- ADAMTS13 Inhibitor Assay
- ADAMTS13 Reflex Panel
- Bethesda Inhibitor
- Coagulation Factor 8 Inhibitor Assay
- Coagulation Factor 9 Inhibitor Assay
- Factor IX Activity w/Reflex to Inhibitor
- Factor IX Activity with Reflex to Bethesda Quantitative, Factor IX
- Factor V (5) w/Reflex to Inhibitor
- Factor VIII Activity w/Reflex to Inhibitor
- Factor VIII Activity with Reflex to Bethesda Quantitative, Factor VIII
- Factor VIII Chromogenic Bethesda Profile, for Patients on Emicizumab
- Factor XI (11) w/Reflex to Inhibitor
- Prolonged Clot Time Reflexive Profile
Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation