Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › Coagulation Specific Factor Inhibitor Assay

Coagulation Specific Factor Inhibitor Assay: Michigan Medicine Laboratories (MLabs) test INH2, INH5, INH7, INH10, INH11, INH12

Michigan Medicine Laboratories (MLabs) test INH2, INH5, INH7, INH10, INH11, INH12, CPT 85335. Specimen: 2 full 2.7mL tubes or 2mL of plasma (two 1 mL aliquots). Turnaround: 3 hours.

Coagulation Specific Factor Inhibitor Assay is Michigan Medicine Laboratories (MLabs) test code INH2, INH5, INH7, INH10, INH11, INH12, billed with CPT 85335. Specimen: 2 full 2.7mL tubes or 2mL of plasma (two 1 mL aliquots). Turnaround time: 3 hours. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories, OHSU Laboratory Services, Labcorp.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeINH2, INH5, INH7, INH10, INH11, INH12
CPT85335
LOINC—
Specimen2 full 2.7mL tubes or 2mL of plasma (two 1 mL aliquots)
Volume2 full 2.7mL tubes or 2mL of plasma (two 1 mL aliquots)
Turnaround time3 hours
Storage / transportRoom temperature for whole blood or frozen aliquot of citrated plasma.

Also known as: Bethesda Inhibitor; Coagulation Factor II Inhibitor Assay; Factor II Inhibitor Assay; Specific Factor Inhibitor Assay; Inhibitor Assay II:C; Inhibitor Assay V:C; Inhibitor Assay VII:C; Inhibitor Assay X:C; Inhibitor Assay XI:C; Inhibitor Assay XII:C; Coagulation Factor V Inhibitor Assay; Factor V Inhibitor Assay; Factor VII Inhibitor Assay; Coagulation Factor X Inhibitor Assay; Factor X Inhibitor Assay; Inhibitor Assay II, V, VII, X, XI, or XII; Coagulation Factor XI Inhibitor Assay; Factor XI Inhibitor Assay; Coagulation Factor XII Inhibitor Assay; Coagulation Factor VII Inhibitor Assay; Factor XII Inhibitor Assay; Factor 7 Inhibitor Assay; Factor 2 Inhibitor Assay; Factor 5 Inhibitor Assay; Factor 10 Inhibitor Assay; Factor 11 Inhibitor Assay; Factor 12 Inhibitor Assay

Use

Detection of inhibitors directed against specific coagulation factors.

Collection instructions

The specific factor assay activity level is included in this order.If the factor activity level is >50%, the inhibitor level will not be performed. Collect specimen in two blue top (citrate 3.2%) tubes. Mix by inversion. Specimen should arrive at lab within 3 hours of collection; transport at room temperature. Alternatively, centrifuge, aliquot plasma from each blue top tube into separate plastic vials, and freeze the specimen within 4 hours of collection. Transport frozen specimen on dry ice. Collection of the blood through lines that have been previously flushed with heparin should be avoided. If the blood must be drawn through a VAD (vascular access device), the line should be flushed with 5 mL of saline and the first 5 mL of blood or six dead space volumes of the VAD discarded.

Reference range

Normal individuals have <0.5 Bethesda units. Critical value is >0.5 Bethesda units if no prior inhibitor has been detected.

Section

Coagulation

Performed

Thursday, starting at 8am.

Contraindications

Test is not indicated if Factor level is greater than 50%, if the patient is receiving anticoagulation therapy, or if the patient is receiving factor replacement therapy.

NY State approved

No

Performing Laboratory

Clinical Core Laboratory

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 85335

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation