Cleveland Clinic Laboratories test ADM13, CPT 85335, 85390, 85397. Specimen: Platelet-poor plasma. Turnaround: 2 - 4 days.

ADAMTS13 Evaluation is Cleveland Clinic Laboratories test code ADM13, billed with CPT 85335, 85390, 85397. Specimen: Platelet-poor plasma. Turnaround time: 2 - 4 days. Performing laboratory: Cleveland Clinic Laboratories, CLIA 36D0656094 (Cleveland, OH). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Labcorp.
LaboratoryCleveland Clinic Laboratories
CLIA number36D0656094
Test codeADM13
CPT85335 - QTY (1); 85390 - QTY (1); 85397 - QTY (1)
LOINC—
SpecimenPlatelet-poor plasma
Volume2 mL
ContainerSodium citrate (Lt. Blue)
Turnaround time2 - 4 days
Storage / transportCentrifuge, aliquot and freeze ASAP.

Test includes

ADAMTS13 Inhibitor Assay; ADAMTS Activity Assay

Methodology

Fluorescence Resonance Energy Transfer (FRET)

Stability

TemperaturePeriod
Ambient4 hrs.
Frozen14 days at -20 C; or

Special instructions

Collection tube must be filled to total fill volume. Inadequately filled tubes will be rejected. Invert to mix 3-4 times. Non-Testing Sites: Centrifuge sample; Aliquot plasma into a separate tube and label with Epic Beaker label. Specimen should be frozen (-20C or colder).

Performed

Mon - Sun

Performing Laboratory

Cleveland Clinic Laboratories

View this test on Cleveland Clinic Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 85335, 85390, 85397

Search the National Lab Test Directory · All Cleveland Clinic Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation