Quality Control, Levey-Jennings Charts and Westgard Rules Course
Practical QC for laboratory staff: mean, SD and CV, Levey-Jennings charts, Westgard multirules, shifts and trends, corrective action and documentation.
Free40 min5 lessons10-question quiz
Lessons
Lesson 1: Why QC statistics
Control materials with known expected values are run alongside patient samples. Plotting results over time shows whether a test system is stable, drifting or failing, before wrong patient results are reported.
Lesson 2: Mean, SD and CV
- The mean is the average of control results; establish it from your own data (for example at least 20 data points) or follow the manufacturer's guidance for new lots.
- The standard deviation (SD) measures spread. About 95% of results fall within plus or minus 2 SD of the mean and about 99.7% within plus or minus 3 SD.
- The coefficient of variation (CV) is SD divided by the mean, times 100%, and lets you compare precision across levels.
Lesson 3: Levey-Jennings charts
A Levey-Jennings chart plots each control result by date with lines at the mean and at plus or minus 1, 2 and 3 SD. Look for single outliers, shifts (several results in a row on one side of the mean, suggesting a systematic change such as a new reagent lot or calibration problem) and trends (results moving steadily in one direction, such as deteriorating reagent or lamp).
Lesson 4: Westgard rules
- 1-2s: one result beyond 2 SD, a warning to inspect other rules.
- 1-3s: one result beyond 3 SD, reject (random error).
- 2-2s: two consecutive results beyond 2 SD on the same side, reject (systematic error).
- R-4s: one control beyond +2 SD and another beyond -2 SD in the same run, reject (random error).
- 4-1s: four consecutive results beyond 1 SD on the same side, reject (systematic error).
- 10x: ten consecutive results on the same side of the mean, reject (systematic error).
Your lab's QC procedure defines which rules apply to each test.
Lesson 5: Corrective action
- Stop reporting patient results.
- Look for the cause: reagents, controls, calibration, instrument, environment, operator.
- Fix it, rerun QC, and document what you found and did.
- Evaluate patient results since the last acceptable QC and issue corrected reports if needed.
Repeating controls until one passes without investigating is not acceptable corrective action.
Quiz and certificate
Answer all 10 questions. Score 80% or higher to get your free certificate from Sound Lab Consultants - Technical Consultants.
Under CLIA, everyone who performs non-waived testing must have documented training before reporting patient results, and documented competency assessment at 6 months and 12 months in the first year and annually after that. The six required methods are direct observation of routine testing, monitoring of recording and reporting of results, review of worksheets, QC and maintenance records, direct observation of maintenance and function checks, testing of previously analyzed or external samples, and assessment of problem-solving skills (42 CFR 493.1451 and 493.1413). Waived testing follows the manufacturer's instructions and your lab's own training and competency policy. This course documents training. It does not replace the competency assessment your laboratory director or technical consultant must perform at your site.
More free courses
PATHFAST Immunoanalyzer Operator Course · Sysmex XP-300 Hematology Analyzer Operator Course · Abaxis Piccolo Xpress Chemistry Analyzer Operator Course · Phlebotomy, Specimen Processing and Transport Course · All courses
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultationor call (602) 874-1311