Cleveland Clinic Laboratories test FIXC, CPT 85250. Specimen: Plasma. Turnaround: 1 - 3 days.
Factor IX Assay is Cleveland Clinic Laboratories test code FIXC, billed with CPT 85250. Specimen: Plasma. Turnaround time: 1 - 3 days. Performing laboratory: Cleveland Clinic Laboratories, CLIA 36D0656094 (Cleveland, OH). Other labs in the directory with tests billed under the same CPT: Labcorp, ARUP Laboratories.
LaboratoryCleveland Clinic Laboratories
CLIA number36D0656094
Test codeFIXC
CPT85250 - QTY (1)
LOINC3187-2
SpecimenPlasma
Volume2 mL
Minimum volume1 mL
ContainerSodium citrate (Lt. Blue)
Turnaround time1 - 3 days
Storage / transportFrozen
Methodology
Clotting Assay
Stability
| Temperature | Period |
|---|---|
| Ambient | 4 hours |
| Refrigerated | Unacceptable |
| Frozen | 14 days at -20 C; 6 months at -70 C |
Special instructions
Indicate previous prothrombin and partial thromboplastin time results on requisition.
Performed
Mon - Fri
Performing Laboratory
Cleveland Clinic Laboratories
View this test on Cleveland Clinic Laboratories's website → · Last checked 2026-11-29
Other tests billed with CPT 85250
- Bethesda Inhibitor
- Bleeding With Normal aPTT/PT
- Factor IX Activity
- Factor IX Activity With Inhibitor Reflex
- Factor IX Activity with Reflex to Bethesda Quantitative, Factor IX
- Factor IX Antigen
- Factor IX, Activity
- Intrinsic Pathway Coagulation Factor Profile
- Prolonged Activated Partial Thromboplastin Time (aPTT)
- Prolonged Clot Time Reflexive Profile
- Prolonged Activated Partial Thromboplastin Time (aPTT)
Search the National Lab Test Directory · All Cleveland Clinic Laboratories tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation