Short answer: For each nonwaived test system, every testing person must be assessed on six elements, twice in the first year (around 6 months and 12 months) and annually after that. Missing competency is one of the most-cited CLIA deficiencies.
The six elements
- Direct observation of routine patient testing, including specimen handling
- Monitoring the recording and reporting of results, including critical values
- Review of intermediate results, QC records, PT results and maintenance records
- Direct observation of instrument maintenance and function checks
- Assessment of performance on previously analyzed specimens, blind samples or PT samples
- Assessment of problem-solving skills
Who can assess
In moderate-complexity labs, the technical consultant or director (or qualified people they delegate in writing). In high-complexity labs, the technical supervisor or general supervisor as allowed.