Factor IX Antigen: Labcorp test 086310
Labcorp test 086310, CPT 85250. Specimen: Plasma, frozen. Turnaround: 5 - 7 days.
Also known as: Factor IX Quantitation (Nonfunctional)
Use
This test is used to measure the level of factor IX antigen in plasma.
Methodology
Enzyme-linked immunosorbent assay (ELISA)
Collection instructions
Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set, a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternative anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Patient preparation
Do not draw from an arm with a heparin lock or heparinized catheter.
Reference range
60–150%
Limitations
This assay should not be used as screening tests for factor IX deficiency given the false-normal values in patients with type II disease. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 086311 | Factor IX Antigen | % | 3190-6 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 85250
- Bethesda Inhibitor
- Bleeding With Normal aPTT/PT
- Factor IX Activity
- Factor IX Activity With Inhibitor Reflex
- Factor IX Activity with Reflex to Bethesda Quantitative, Factor IX
- Factor IX Assay
- Factor IX, Activity
- Intrinsic Pathway Coagulation Factor Profile
- Prolonged Activated Partial Thromboplastin Time (aPTT)
- Prolonged Clot Time Reflexive Profile
- Prolonged Activated Partial Thromboplastin Time (aPTT)
Search the National Lab Test Directory · All Labcorp tests and CLIA locations