Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › OHSU Laboratory Services › Factor IX Activity

Factor IX Activity: OHSU Laboratory Services test LAB00255

OHSU Laboratory Services test LAB00255, CPT 85250. Specimen: 3.2% sodium citrate tubes are acceptable when they are filed to the line on the manufacturers label. Tubes must be full . Turnaround: Routine: 4 Hours.

Factor IX Activity is OHSU Laboratory Services test code LAB00255, billed with CPT 85250. Specimen: 3.2% sodium citrate tubes are acceptable when they are filed to the line on the manufacturers label. Tubes must be full (see comments below). Turnaround time: Routine: 4 Hours. Performing laboratory: OHSU Laboratory Services, CLIA 38D0676694 (Portland, OR). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Labcorp, Michigan Medicine Laboratories (MLabs), ARUP Laboratories.
LaboratoryOHSU Laboratory Services
CLIA number38D0676694
Test codeLAB00255
CPT85250 x 1 (Factor IX Activity)
LOINC—
Specimen3.2% sodium citrate tubes are acceptable when they are filed to the line on the manufacturers label. Tubes must be full (see comments below). For referral testing, submit 2 x 1.0 mL frozen platelet poor citrated plasma. Sodium citrate specimens must be processed and frozen within 1 hour of specimen collection. OHSU clinics must cab specimen to the Core Lab, Hatfield Research Center (HRC), Room 9D05 if processing is delayed or not possible on site. A phone call is helpful to alert the lab at 503-494-5764. Detailed instructions are under Hemostasis & Thrombosis section (Opens in a new window) .
Turnaround timeRoutine: 4 Hours Urgent: 60 Minutes

Also known as: F9A; Factor IX; Factor 9

Reference range

Reference Range: 65% to 150%

Special instructions

Draw volume is critical due to the liquid anticoagulant. Allow tubes to fill by vacuum. Tubes with rubber stopper: fill to line on label. Tubes with plastic (Hemogard) cap: the fill level is above the top of the label. Syringe: do not remove the vacutainer stopper. Insert the needle through the stopper and allow the tube to fill by vacuum. Do not overfill the vacutainer. Pediatric tubes have no vacuum. Remove the cap and add blood to the 1.3 mL mark. Do not overfill. Avoid warfarin (Coumadin) therapy for 2 weeks and heparin therapy for 2 days prior to the test. Assay to document Factor IX deficiency. Factor IX deficiency (PTC or plasma thromboplastin component or Christmas disease) is commonly referred to as hemophilia B. It has a recessive sex-linked mode of inheritance, males are affected, females are carriers. It occurs in 1 of 25,000 males. Low levels of factor IX may be present in patients with liver disease. Severity of the symptoms correlate directly with the degree of prolongation of APTT test (level of factor IX deficiency). Mildly affected patient may show excessive bleeding only with major trauma or surgery. The APTT may not be prolonged if the factor IX level is over 25%. In most cases of hemophilia B, the prothrombin time and thrombin times are normal. A subgroup of cross reacting material positive hemophilia B patients, however, is defined by its markedly prolonged ox-brain prothrombin time. The molecular defect of this "hemophilia Bm" (factor IXHilo) has recently been described. Methodology: APTT based clotting assay.

Units

%

Section

Core Lab

Performed

24 hours, 7 days a week.

Pediatric specimen

Pediatric tubes are acceptable when they are filed to the line on the manufacturers label. Add blood to the 1.3 mL mark of Pediatric BLUE top tube, 3.2% sodium citrate. For pediatric patients requiring multiple coagulation tests, please call 503-494-7383 regarding draw volumes.

View this test on OHSU Laboratory Services's website → · Last checked 2026-11-29

Other tests billed with CPT 85250

Search the National Lab Test Directory · All OHSU Laboratory Services tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.