Factor IX Activity With Inhibitor Reflex: Labcorp test 086300
Labcorp test 086300, CPT 85250. Specimen: Plasma, frozen. Turnaround: 5 - 7 days.
Also known as: Factor IX Inactivator; Factor IX Bethesda Titer
Test includes
This test includes factor IX Activity with reflex to factor IX inhibitor (Bethesda titer) when activity is less than or equal to 40%.
Use
This profile measures factor IX activity and reflexes to a measurement of factor IX inhibitor level (Bethesda titer) when the activity level is diminished to 40% or less.
Methodology
See individual activity test information for method information. The Bethesda titer measures the amount (titer) of an inhibitor antibody against a specific clotting factor. The test uses dilutions of the patient's plasma and determines the amount of antibody needed to neutralize 50% of the factor activity provided by pooled normal plasma with results expressed in Bethesda units (BUs). One Bethesda Unit (BU) is defined as the amount of an inhibitor that will neutralize 50% of one unit of the factor in normal plasma after 120 minutes incubation at 37°C. A higher titer indicates a stronger inhibitor, which can significantly impact treatment. A Bethesda titer assay is not performed when factor…
Collection instructions
Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternative anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Stability
| Temperature | Period |
|---|---|
| Frozen | 28 days |
| Freeze/thaw cycles | Stable x3 |
Patient preparation
Ideally, the patient should not be on anticoagulant therapy. Avoid warfarin (Coumadin®) therapy for two weeks prior to the test and heparin, direct Xa and thrombin inhibitor therapies for about three days prior to testing. Do not draw from an arm with a heparin lock or heparinized catheter.
Causes for rejection
Severe hemolysis; improper labeling; clotted specimen; specimen diluted with IV fluids; samples thawed in transit; improper sample type; sample out of stability
Reference range
Age Range 1 d 35–56% 3 d 44–97% 1 to 11 m 43–121% 1 to 5 y 44–127% 6 to 10 y 48–145% 11 to 16 y 64–216% >16 y 59–143%
Special instructions
If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 086298 | Factor IX Activity | % | 3187-2 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 85250
- Bethesda Inhibitor
- Bleeding With Normal aPTT/PT
- Factor IX Activity
- Factor IX Activity with Reflex to Bethesda Quantitative, Factor IX
- Factor IX Antigen
- Factor IX Assay
- Factor IX, Activity
- Intrinsic Pathway Coagulation Factor Profile
- Prolonged Activated Partial Thromboplastin Time (aPTT)
- Prolonged Clot Time Reflexive Profile
- Prolonged Activated Partial Thromboplastin Time (aPTT)
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation