Factor IX, Activity: ARUP Laboratories test 0030100
ARUP Laboratories test 0030100, CPT 85250. Specimen: Lt. blue (sodium citrate). Refer to Specimen Handling at aruplab.com for hemostasis/thrombosis specimen handling guideli. Turnaround: 1-3 days.
Factor IX, Activity is ARUP Laboratories test code 0030100, billed with CPT 85250. Specimen: Lt. blue (sodium citrate). Refer to Specimen Handling at aruplab.com for hemostasis/thrombosis specimen handling guidelines.. Turnaround time: 1-3 days. Performing laboratory: ARUP Laboratories, CLIA
46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Labcorp.
Test code0030100
CPT85250
LOINC3187-2
SpecimenLt. blue (sodium citrate). Refer to Specimen Handling at aruplab.com for hemostasis/thrombosis specimen handling guidelines.
Turnaround time1-3 days
Storage / transportCRITICAL FROZEN. Separate specimens must be submitted when multiple tests are ordered.
Also known as: Christmas Factor; Coagulation Factor IX Activity Assay, Plasma; Intrinsic Factor Proteins; Intrinsic Factors; Plasma Thromboplastin Component; PTC; Antihemophilic Factor B
Use
Order to diagnose factor IX deficiency (hemophilia B) and monitor factor IX replacement therapy.
Methodology
Electromagnetic Mechanical Clot Detection
Collection instructions
Transfer 2 mL platelet-poor plasma to an ARUP Standard Transport Tube. (Min: 1 mL)
Stability
Ambient: 4 hours; Refrigerated: Unacceptable; Frozen: 2 weeks
Causes for rejection
Serum. EDTA plasma, clotted or hemolyzed specimens.
Reference range
Age
Reference Interval
Age
Reference Interval
1-4 days
15-91%
7-9 years
70-133%
5-29 days
15-91%
10-11 years
72-149%
30-89 days
21-81%
12-13 years
73-152%
90-179 days
21-113%
14-15 years
80-161%
180-364 days
36-136%
16-17 years
86-176%
1-5 years
47-104%
18 years and older
78-184%
6 years
63-89%
Performed
Mon-Sat
Compliance Category
Standard
New York DOH Approval Status
This test is New York state approved.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|
| 0030100 | Factor IX, Activity | | 3187-2 |
View this test on ARUP Laboratories's website → · Last checked 2026-11-29
Other tests billed with CPT 85250
- Bethesda Inhibitor
Cleveland Clinic LaboratoriesTest code BETHDACPT 85210, 85220, 85230, 85240, 85250, 85260, 85270, 85335PlasmaTAT 1 - 3 days
- Bleeding With Normal aPTT/PT
LabcorpTest code 117700CPT 85240, 85245, 85246, 85250, 85270, 85291, 85384, 85410, 85415Plasma (3.2% citrated), frozenTAT 4 - 5 days
- Factor IX Activity
LabcorpTest code 086298CPT 85250Plasma, frozenTAT 2 - 3 days
- Factor IX Activity With Inhibitor Reflex
LabcorpTest code 086300CPT 85250Plasma, frozenTAT 5 - 7 days
- Factor IX Activity with Reflex to Bethesda Quantitative, Factor IX
ARUP LaboratoriesTest code 0030032CPT 85250, 85335Lt. blue (sodium citrate). Refer to Specimen Handling at aruplab.com for hemostaTAT 1-3 days
- Factor IX Antigen
LabcorpTest code 086310CPT 85250Plasma, frozenTAT 5 - 7 days
- Factor IX Assay
Cleveland Clinic LaboratoriesTest code FIXCCPT 85250PlasmaTAT 1 - 3 days
- Intrinsic Pathway Coagulation Factor Profile
LabcorpTest code 500033CPT 85240, 85250, 85270, 85280Plasma, frozenTAT 2 - 3 days
- Prolonged Activated Partial Thromboplastin Time (aPTT)
LabcorpTest code 117796CPT 85240, 85250, 85270, 85280, 85613, 85732Plasma, frozenTAT 2 - 3 days
- Prolonged Clot Time Reflexive Profile
ARUP LaboratoriesTest code 3006383CPT 85210, 85220, 85230, 85240, 85245, 85246, 85250, 85260, 85270, 85280, 85335, 85379, 85384, 85385, 85390, 85397, 85520, 85525, 85598, 85610, 85611, 85613, 85670, 85730, 85732At least five light blue (sodium citrate) tubes. Refer to Specimen Handling at aTAT 2-10 days
- Prolonged Activated Partial Thromboplastin Time (aPTT)
LabcorpTest code 117796Women's HealthCPT 85240, 85250, 85270, 85280, 85613, 85732Plasma, frozenTAT 2 - 3 days
Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code.
Submit your lab's test menu → Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation