Sound Lab Consultants › National Lab Test Directory › Labcorp › Factor VIII Chromogenic Bethesda Profile, for Patients on Emicizumab

Factor VIII Chromogenic Bethesda Profile, for Patients on Emicizumab: Labcorp test 504722

Labcorp test 504722, CPT 85240, 85335. Specimen: Citrated plasma, frozen. Turnaround: 5 - 10 days.

Factor VIII Chromogenic Bethesda Profile, for Patients on Emicizumab is Labcorp test code 504722, billed with CPT 85240, 85335. Specimen: Citrated plasma, frozen. Turnaround time: 5 - 10 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code504722
CPT85240(x2); 85335
LOINC3209-4, 49865-9, 93450-5
SpecimenCitrated plasma, frozen
Volume2 mL
Minimum volume1 mL
ContainerBlue-top (sodium citrate) tube
Turnaround time5 - 10 days
Storage / transportFreeze.

Use

This assay is used to quantitate the titer of specific factor VIII antibodies in patients receiving emicizumab / Hemlibra®. Use of a standard, clot-based factor VIII test system will not accurately determine inhibitor titer due to interference from the therapeutic.

Methodology

The Nijmegen modification of the classic Bethesda inhibitor titration assay is used in a chromogenic factor VIII activity setting. Patient sample is heat-inactivated and clarified, then a serial dilution series is prepared in buffered normal plasma containing bovine serum albumin. A chromogenic factor activity is measured to determine residual activity and the inhibitor concentration is determined using an equation that relates the log % residual activity to inhibitor titer.

Collection instructions

Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples, except when using a winged blood collection device (ie, "butterfly"), in which case a discard tube should be used.When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.

Stability

TemperaturePeriod
Frozen12 months
Freeze/thaw cyclesStable x5

Patient preparation

The patient should not be anticoagulated. Do not draw from an arm with a heparin lock or heparinized catheter.

Causes for rejection

Patients on any therapy other than emicizumab therapy. Any sample other than citrated plasma (3.2% sodium citrate). Samples showing signs of activation, including the presence of fibrin clots, or received thawed.

Special instructions

Testing is performed at Esoterix Coagulation Laboratory (UY No. 301676). For use in the confirmation and characterization of factor VIII inhibitors for patients on emicizumab therapy. Not intended for use with any other therapeutic.

Limitations

Hemolysis, lipemia and icterus may interfere with this assay. Certain anticoagulant drugs (direct Xa inhibitors) may lead to an erroneously low factor activity and erroneously positive specific factor inhibitor results. Residual factor VIII activity could falsely lower the Bethesda titer although this is limited by heat-inactivation of the patient sample. Autoimmune inhibitors that demonstrate second order kinetics cannot always be accurately measured in the Bethesda titer system.

LOINC map

Result codeResult nameUnitsResult LOINC
Factor VIII Activity%3209-4
FVIII Chromogenic%49865-9
FVIII Chrom Nijmegen BethesdaCBU/mL93450-5

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 85240, 85335

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation