Factor VIII Chromogenic Bethesda Profile, for Patients on Emicizumab: Labcorp test 504722
Labcorp test 504722, CPT 85240, 85335. Specimen: Citrated plasma, frozen. Turnaround: 5 - 10 days.
Use
This assay is used to quantitate the titer of specific factor VIII antibodies in patients receiving emicizumab / Hemlibra®. Use of a standard, clot-based factor VIII test system will not accurately determine inhibitor titer due to interference from the therapeutic.
Methodology
The Nijmegen modification of the classic Bethesda inhibitor titration assay is used in a chromogenic factor VIII activity setting. Patient sample is heat-inactivated and clarified, then a serial dilution series is prepared in buffered normal plasma containing bovine serum albumin. A chromogenic factor activity is measured to determine residual activity and the inhibitor concentration is determined using an equation that relates the log % residual activity to inhibitor titer.
Collection instructions
Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples, except when using a winged blood collection device (ie, "butterfly"), in which case a discard tube should be used.When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Stability
| Temperature | Period |
|---|---|
| Frozen | 12 months |
| Freeze/thaw cycles | Stable x5 |
Patient preparation
The patient should not be anticoagulated. Do not draw from an arm with a heparin lock or heparinized catheter.
Causes for rejection
Patients on any therapy other than emicizumab therapy. Any sample other than citrated plasma (3.2% sodium citrate). Samples showing signs of activation, including the presence of fibrin clots, or received thawed.
Special instructions
Testing is performed at Esoterix Coagulation Laboratory (UY No. 301676). For use in the confirmation and characterization of factor VIII inhibitors for patients on emicizumab therapy. Not intended for use with any other therapeutic.
Limitations
Hemolysis, lipemia and icterus may interfere with this assay. Certain anticoagulant drugs (direct Xa inhibitors) may lead to an erroneously low factor activity and erroneously positive specific factor inhibitor results. Residual factor VIII activity could falsely lower the Bethesda titer although this is limited by heat-inactivation of the patient sample. Autoimmune inhibitors that demonstrate second order kinetics cannot always be accurately measured in the Bethesda titer system.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| Factor VIII Activity | % | 3209-4 | |
| FVIII Chromogenic | % | 49865-9 | |
| FVIII Chrom Nijmegen Bethesda | CBU/mL | 93450-5 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 85240, 85335
- Bethesda Inhibitor
- Bleeding With Normal aPTT/PT
- Chromogenic Factor VIII, Activity
- COVID-19 Induced Thrombotic Microangiopathy Profile
- DDAVP (Desmopressin) Challenge Profile
- Disseminated Intravascular Coagulation (DIC) Profile, Comprehensive Plus
- Factor VIII Activity
- Factor VIII Activity With Inhibitor Reflex
- Factor VIII Activity with Reflex to Bethesda Quantitative, Factor VIII
- Factor VIII Assay
- Factor VIII Chromogenic
- Factor VIII Inhibitor Profile, Comprehensive
- Factor VIII, Activity
- Hypercoagulation Diagnostic Interpretive Panel
- Intrinsic Pathway Coagulation Factor Profile
- Lupus Anticoagulant Diagnostic Interpretive Panel
- Menorrhagia Profile
- Post DDAVP Monitoring
- Pre DDAVP Monitoring
- Prolonged Activated Partial Thromboplastin Time (aPTT)
- Prolonged Clot Time Reflexive Profile
- Thrombotic Risk, Congenital (Extended)
- von Willebrand Diagnostic Interpretive Panel (Limited)
- von Willebrand Disease Type 2N Binding
- von Willebrand Factor Disease (vWD) Profile
- von Willebrand Factor Disease (vWD) Reflex Profile
- von Willebrand Factor Multimeric Panel
- von Willebrand Factor Panel
- von Willebrand Factor Panel With Reflex to von Willebrand Multimers
- Menorrhagia Profile
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation