Michigan Medicine Laboratories (MLabs) test DIC, CPT 85049, 85379, 85384, 85610, 85730. Specimen: Blue top 3.2% sodium citrate tube. Turnaround: 1 hour.

Disseminated Intravascular Coagulation (DIC) Panel is Michigan Medicine Laboratories (MLabs) test code DIC, billed with CPT 85049, 85379, 85384, 85610, 85730. Specimen: Blue top 3.2% sodium citrate tube. Turnaround time: 1 hour. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: Labcorp, Quest Diagnostics, Allina Health Laboratory (Abbott Northwestern), Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeDIC
CPT85379, 85384, 85049, 85610, 85730
LOINC—
SpecimenBlue top 3.2% sodium citrate tube Full 2.7 mL tube or 1 mL plasma aliquot Lavender top EDTA K2: 3mL EDTA K2 whole blood or 500 uL whole blood in an EDTA K2 Microtainer® tube
VolumeBlue top 3.2% sodium citrate tube Full 2.7 mL tube or 1 mL plasma aliquot Lavender top EDTA K2: 3mL EDTA K2 whole blood or 500 uL whole blood in an EDTA K2 Microtainer® tube
Turnaround time1 hour

Also known as: Consumptive Coagulopathy; DIC Workup; DIC Panel

Use

Aid in diagnosis when Disseminated Intravascular Coagulation (DIC) is suspected. Decreased platelet count, elevated D-Dimers, prolonged PT and aPTT, and decreased fibrinogen are markers of DIC.

Collection instructions

This test requires both a blue top and lavender top tube. 1. Collect specimen in a blue top sodium citrate 3.2% Vacutainer® tube. Mix by inversion. Specimen should arrive at lab within 3 hours of collection; transport at room temperature. Alternatively, centrifuge, aliquot plasma into a plastic vial, and freeze the specimen within 4 hours of collection. Transport frozen specimen on dry ice. Collection of the blood through lines that have been previously flushed with heparin should be avoided. If the blood must be drawn through a VAD (vascular access device), the line should be flushed with 5 mL of saline and the first 5 mL of blood or six dead space volumes of the VAD discarded. 2. Collect additional specimen in a lavender top EDTA K2 Vacutainer® tube or EDTA K2 Microtainer® tube. Send intact whole blood specimen within 24 hours if stored at room temperature or 48 hours if refrigerated.

Section

Coagulation

Performed

Daily, 24 hours

NY State approved

No

Performing Laboratory

Clinical Core Laboratory

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 85049, 85379, 85384

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation