Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Disseminated Intravascular Coagulation (DIC) Profile

Disseminated Intravascular Coagulation (DIC) Profile: Labcorp test 116012

Labcorp test 116012, CPT 85049, 85362, 85379, 85384, 85610, 85730. Specimen: Whole blood and plasma, frozen. Turnaround: 2 - 3 days.

Disseminated Intravascular Coagulation (DIC) Profile is Labcorp test code 116012, billed with CPT 85049, 85362, 85379, 85384, 85610, 85730. Specimen: Whole blood and plasma, frozen. Turnaround time: 2 - 3 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code116012
CPT85049; 85362; 85379; 85384; 85610; 85730
LOINC14979-9, 30226-5, 3255-7, 5902-2
SpecimenWhole blood and plasma, frozen
Volume5 mL EDTA whole blood, one citrated whole blood tube, and two transfer tubes with 1 mL frozen sodium citrate plasma in each tube
ContainerLavender-top (EDTA) tube and blue-top (sodium citrate) tubes
Turnaround time2 - 3 days
Storage / transportMaintain whole blood at room temperature. Freeze plasma.

Also known as: DIC Profile

Test includes

This test includes D-dimer; fibrinogen; fibrinogen degradation products (FDP), plasma; platelet count; partial thromboplastin time (PTT); and prothrombin time (PT).

Use

This test is used to identify the presence and follow the course of disseminated intravascular coagulation (DIC).

Methodology

See individual tests.

Collection instructions

Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge and carefully remove the plasma using a plastic transfer pipette, being careful not to disturb the cells. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.

Patient preparation

None

Causes for rejection

Severe hemolysis; improper labeling; clotted specimen; specimen diluted with IV fluids; samples thawed in transit; improper sample type; sample out of stability

Special instructions

If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions.

LOINC map

Result codeResult nameUnitsResult LOINC
Fibrinogen Activitymg/dL3255-7
FDP, Plasmaug/mL30226-5
015289Prothrombin Timesec5902-2
aPTTsec14979-9

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 85049, 85362, 85379

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation