Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Allina Health Laboratory (Abbott Northwestern) › D-Dimer, quantitative

D-Dimer, quantitative: Allina Health Laboratory (Abbott Northwestern) test 3433

Allina Health Laboratory (Abbott Northwestern) test 3433, CPT 85379. Specimen: Sodium citrate (Na cit) plasma. Turnaround: 1 day.

D-Dimer, quantitative is Allina Health Laboratory (Abbott Northwestern) test code 3433, billed with CPT 85379. Specimen: Sodium citrate (Na cit) plasma. Turnaround time: 1 day. Performing laboratory: Allina Health Laboratory (Abbott Northwestern), CLIA 24D0401558 (Minneapolis, MN). Other labs in the directory with tests billed under the same CPT: Labcorp, ARUP Laboratories, Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryAllina Health Laboratory (Abbott Northwestern)
CLIA number24D0401558
Test code3433
CPT85379
LOINC—
SpecimenSodium citrate (Na cit) plasma
Volume2.0 mL
ContainerLt blue Sodium citrate (Na Cit) - 2.7mL If the patient has a hematocrit >55, a specially prepared Lt blue Sodium citrate (NaCit) tube must be used in place of the standard Lt blue Sodium citrate (NaCit) tube. Hematocrit-Anticoagulant adjustments
Turnaround time1 day

Also known as: FDP; Fibrin degradation products; XDP

Use

The D-Dimer is a terminal product in the degradation of fibrin. The D-Dimer is proof that the fibrinolytic system is responding to some coagulation activation. Increased levels of the D-Dimer are seen in: DIC Thromboses: Deep vein thrombosis (DVT) or in Pulmonary Emboli (PE). The D-Dimer can be used as a negative predictor value to rule out these conditions. Other activation of coagulation system: Cancers, post-operative stage, cirrhosis, hemorrhages.

Methodology

Immuno-turbidimetric

Collection instructions

Do not over or under fill tube as the ratio of anticoagulant to whole blood is critical Coag – tube fill guidelines Immediately following collection, mix sample thoroughly by gentle inverting 8 - 10 times to prevent clotting

Stability

Plasma: Frozen (strict) Refrigerated - NO Whole blood: Ambient - 4 hours Refrigerated - NO

Causes for rejection

Improper label (unlabeled or mislabeled) Improper anticoagulant Improperly filled tube Hemolysis Clotted specimen Delay in transport/exceeds standard testing time Improper storage/transport temperature Unlabled specimen Patient on heparin > 1.0 IU/mL Specimens collected in Grenier tubesPlasma samples that are not completely frozen

Reference range

< 0.5 µg/mL For patients greater than 50 years of age, the upper limit is age dependent and was calculated with the formula: (Patient Age x 0.01) FEU mcg/mL = Upper limit of normal range

Performed

Daily

Abbreviation

DD

Order number

85379.0

Alternate specimens

Sodium citrate (Na cit) whole blood - STAT requests only Alternate processing instructions: Send whole blood sample in original collection container with STAT courier. Must be tested within 4 hours of collection. Alternate transport container: Lt blue Sodium citrate (NaCit) - 2.7mL

Transport container

Microcentrifuge vial/tube in a Snap cap conical vial/tube and cap (Beaker sites) Coagulation specimen transport vial/tube (all other sites)

Performing Laboratory

AHL - Coagulation: W

Processing instructions

Process Platelet Poor Plasma (P.P.P) Coag – how to prepare a specimen for special coagulation testing Transfer plasma into an aliquot tube using a spot label "NaCit Plasma P.P.P" to label as platelet poor plasma Freeze immediately

View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29

Other tests billed with CPT 85379

Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation