Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Platelet Count

Platelet Count (Women's Health): Labcorp test 005249

Labcorp test 005249, CPT 85049. Specimen: Whole blood. Peripheral blood smears prepared at the time of collection may also be useful, particularly when platelet a. Turnaround: Within 1 day.

Platelet Count is Labcorp test code 005249, billed with CPT 85049. Specimen: Whole blood. Peripheral blood smears prepared at the time of collection may also be useful, particularly when platelet aggregation is a prob. Turnaround time: Within 1 day. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code005249 (Women's Health)
CPT85049
LOINC777-3
SpecimenWhole blood. Peripheral blood smears prepared at the time of collection may also be useful, particularly when platelet aggregation is a problem.
VolumeTube fill capacity
Minimum volume0.5 mL (500 μL for pediatric microtainer capillary tubes; fill tube to capacity.) ( Note: This volume does not allow for repeat testing.)
ContainerLavender-top (EDTA) tube.
Turnaround timeWithin 1 day
Storage / transportMaintain specimen at room temperature.

Also known as: Platelets; Thrombocyte Count

Use

Evaluate, diagnose, and/or follow up bleeding disorders, drug-induced thrombocytopenia, idiopathic thrombocytopenia purpura (acute or chronic), disseminated intravascular coagulation, leukemia states, chemotherapeutic management of malignant disease states; investigate purpura, petechiae; evaluate response to platelet transfusions, steroids, or other therapy

Methodology

Automated cell counter; microscopic exam of peripheral smear if specific criteria are met

Collection instructions

Invert tube immediately 8 to 10 times once tube is filled at time of collection.

Stability

TemperaturePeriod
Room temperature1 day
Refrigerated3 days
FrozenUnstable
Freeze/thaw cyclesUnstable

Causes for rejection

Hemolysis; clotted specimen; tube not filled with minimum volume; improper labeling; transfer tubes with whole blood; specimen diluted or contaminated with IV fluid; specimen received with plasma removed; specimen collected in any anticoagulant other than EDTA

Limitations

Clumping may cause false low count. Platelet satellitism around neutrophils will cause a pseudothrombocytopenia. RBC or WBC fragments including fragmented fragile leukemic cells and neutrophil pseudoplatelets may cause falsely elevated counts.

LOINC map

Result codeResult nameUnitsResult LOINC
015172Plateletsx10E3/uL777-3

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 85049

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation