Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › D-Dimer

D-Dimer: Labcorp test 115188

Labcorp test 115188, CPT 85379. Specimen: Plasma, frozen. Turnaround: Within 1 day.

D-Dimer is Labcorp test code 115188, billed with CPT 85379. Specimen: Plasma, frozen. Turnaround time: Within 1 day. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code115188
CPT85379
LOINC48065-7
SpecimenPlasma, frozen
Volume2 mL
Minimum volume1 mL
ContainerBlue-top (sodium citrate) tube
Turnaround timeWithin 1 day
Storage / transportFreeze , unless testing performed within eight hours of collection.

Use

The D-dimer test is intended for use in conjunction with a clinical pretest probability (PTP) assessment model to exclude pulmonary embolism (PE) and deep venous thrombosis (DVT) in outpatients suspected of PE or DVT.

Methodology

Immunoturbidimetric assay

Collection instructions

Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove / 3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap, and recentrifuge for 10 minutes. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze plasma immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested . Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.

Stability

TemperaturePeriod
Room temperature8 hours
Refrigerated8 hours
Frozen4 weeks
Freeze/thaw cyclesStable x1

Causes for rejection

Gross hemolysis; clotted specimen; specimen thawed in transit; improper labeling; samples stored unfrozen for more than eight hours

Reference range

0.00−0.49 mg/L FEU (Fibrinogen equivalent units) Age (Years) Age-Adjusted Cutoff (mg/L FEU) 0.00−0.50 0.00−0.51 0.00−0.52 0.00−0.53 0.00−0.54 0.00−0.55 0.00−0.56 0.00−0.57 0.00−0.58 0.00−0.59 0.00−0.60 0.00−0.61 0.00−0.62 0.00−0.63 0.00−0.64 0.00−0.65 0.00−0.66 0.00−0.67 0.00−0.68 0.00−0.69 0.00−0.70 0.00−0.71 0.00−0.72 0.00−0.73 0.00−0.74 0.00−0.75 0.00−0.76 0.00−0.77 0.00−0.78 0.00−0.79 0.00−0.80 0.00−0.81 0.00−0.82 0.00−0.83 0.00−0.84 0.00−0.85 0.00−0.86 0.00−0.87 0.00−0.88 0.00−0.89 0.00−0.90 0.00−0.91 0.00−0.92 0.00−0.93 0.00−0.94 0.00−0.95 0.00−0.96 0.00−0.97 0.00−0.98 0.00−0.99

Special instructions

If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions.

Limitations

In outpatients with a low or moderate clinical pretest probability (PTP), a D-dimer result below the selected threshold is consistent with absence of significant intravascular fibrin formation and supports exclusion of venous thromboembolism when interpreted in conjunction with an appropriate validated clinical assessment model. In this population, an elevated result does not confirm pulmonary embolism or deep vein thrombosis but indicates that further imaging may be warranted. D-dimer may also be elevated in non-thrombotic conditions such as disseminated intravascular coagulation, malignancy, infection, recent surgery or trauma, pregnancy and with increasing age. This assay is not suitable…

LOINC map

Result codeResult nameUnitsResult LOINC
115206D-Dimermg/L FEU48065-7

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 85379

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation