D-Dimer: Labcorp test 115188
Labcorp test 115188, CPT 85379. Specimen: Plasma, frozen. Turnaround: Within 1 day.
Use
The D-dimer test is intended for use in conjunction with a clinical pretest probability (PTP) assessment model to exclude pulmonary embolism (PE) and deep venous thrombosis (DVT) in outpatients suspected of PE or DVT.
Methodology
Immunoturbidimetric assay
Collection instructions
Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove / 3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap, and recentrifuge for 10 minutes. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze plasma immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested . Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Stability
| Temperature | Period |
|---|---|
| Room temperature | 8 hours |
| Refrigerated | 8 hours |
| Frozen | 4 weeks |
| Freeze/thaw cycles | Stable x1 |
Causes for rejection
Gross hemolysis; clotted specimen; specimen thawed in transit; improper labeling; samples stored unfrozen for more than eight hours
Reference range
0.00−0.49 mg/L FEU (Fibrinogen equivalent units) Age (Years) Age-Adjusted Cutoff (mg/L FEU) 0.00−0.50 0.00−0.51 0.00−0.52 0.00−0.53 0.00−0.54 0.00−0.55 0.00−0.56 0.00−0.57 0.00−0.58 0.00−0.59 0.00−0.60 0.00−0.61 0.00−0.62 0.00−0.63 0.00−0.64 0.00−0.65 0.00−0.66 0.00−0.67 0.00−0.68 0.00−0.69 0.00−0.70 0.00−0.71 0.00−0.72 0.00−0.73 0.00−0.74 0.00−0.75 0.00−0.76 0.00−0.77 0.00−0.78 0.00−0.79 0.00−0.80 0.00−0.81 0.00−0.82 0.00−0.83 0.00−0.84 0.00−0.85 0.00−0.86 0.00−0.87 0.00−0.88 0.00−0.89 0.00−0.90 0.00−0.91 0.00−0.92 0.00−0.93 0.00−0.94 0.00−0.95 0.00−0.96 0.00−0.97 0.00−0.98 0.00−0.99
Special instructions
If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions.
Limitations
In outpatients with a low or moderate clinical pretest probability (PTP), a D-dimer result below the selected threshold is consistent with absence of significant intravascular fibrin formation and supports exclusion of venous thromboembolism when interpreted in conjunction with an appropriate validated clinical assessment model. In this population, an elevated result does not confirm pulmonary embolism or deep vein thrombosis but indicates that further imaging may be warranted. D-dimer may also be elevated in non-thrombotic conditions such as disseminated intravascular coagulation, malignancy, infection, recent surgery or trauma, pregnancy and with increasing age. This assay is not suitable…
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 115206 | D-Dimer | mg/L FEU | 48065-7 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 85379
- Coagulation Activation Profile
- COVID-19 Induced Thrombotic Microangiopathy Profile
- COVID-19 Poor Outcomes Risk Profile
- COVID-19 Severe Disease Progression Risk Profile
- COVID-19 Triage Profile
- D-Dimer
- D-Dimer
- DIC Panel
- Disseminated Intravascular Coagulation (DIC) Profile
- Disseminated Intravascular Coagulation (DIC) Profile, Comprehensive Plus
- Fibrinolysis Profile
- Prolonged Clot Time Reflexive Profile
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation