Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › COVID-19 Severe Disease Progression Risk Profile

COVID-19 Severe Disease Progression Risk Profile: Labcorp test 164049

Labcorp test 164049, CPT 82728, 83529, 83615, 83880, 84145, 85025, 85379, 86140. Specimen: Serum, plasma, and whole blood. Turnaround: 2 - 4 days.

COVID-19 Severe Disease Progression Risk Profile is Labcorp test code 164049, billed with CPT 82728, 83529, 83615, 83880, 84145, 85025, 85379, 86140. Specimen: Serum, plasma, and whole blood. Turnaround time: 2 - 4 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code164049
CPT82728; 83529; 83615; 83880; 84145; 85025; 85379; 86140
LOINC14804-9, 1988-5, 2276-4, 26881-3, 33762-6, 33959-8, 4544-3, 48065-7
SpecimenSerum, plasma, and whole blood
Volume5 mL serum, 2 mL plasma (sodium citrate), and 4 mL whole blood (EDTA)
Minimum volume3.5 mL serum, 1 mL plasma (sodium citrate), and 4 mL whole blood ( Note: This volume does not allow for repeat testing.)
ContainerGel-barrier tube, blue-top (sodium citrate) tube, and lavender-top (EDTA) tube
Turnaround time2 - 4 days
Storage / transportFrozen: Serum and plasma Room temperature: Serum and whole blood (EDTA)

Test includes

C-Reactive Protein (CRP), Quantitative; D-Dimer; Ferritin, Serum; Interleukin-6, Serum; Lactic Acid Dehydrogenase (LD); Neutrophil to Lymphocyte Ratio (NLR), Complete Blood Count (CBC) With Differential and Platelet; NT-proBNP; Procalcitonin

Use

Comprehensive panel for the assessment of patients at risk of severe COVID-19 disease progression

Methodology

See individual test components.

Collection instructions

Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge and carefully remove the plasma using a plastic transfer pipette, being careful not to disturb the cells.Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No 49482). Freeze plasma within four hours of blood collection and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit seperate frozen specimens for each test requested.

Special instructions

This test may exhibit interference when sample is collected from a person who is consuming a supplement with a high dose of biotin (also termed as vitamin B7 or B8, vitamin H, or coenzyme R). It is recommended to ask all patients who may be indicated for this test about biotin supplementation. Patients should be cautioned to stop biotin consumption at least 72 hours prior to the collection of a sample.

Limitations

For Interleukin-6, Serum [140916]: This test has not been FDA cleared or approved. This test has been authorized by FDA under and EUA for use by authorized laboratories. This test has been authorized only to assist in identifying severe inflammatory response, when used as an aid in determining the risk of intubation with mechanical ventilation in confirmed COVID-19 patients. This test is only authorized for the duration of the declaration that circumstances exist justifying the authorization of emergency use of medical devices under Section 564(b)(1) of the Act, 21 U.S.C. & 360bbb-3(b), unless the authorization is terminated or revoked sooner. Further limitations include: • For diagnostic…

LOINC map

Result codeResult nameUnitsResult LOINC
LDHIU/L14804-9
Ferritinng/mL2276-4
Interleukin-6, Serumpg/mL26881-3
NT-proBNPpg/mL33762-6
Procalcitoninng/mL33959-8
C-Reactive Protein, Quantmg/L1988-5
D-Dimermg/L FEU48065-7
WBCx10E3/uL6690-2
RBCx10E6/uL789-8
Hemoglobing/dL718-7
Hematocrit%4544-3
MCVfL787-2
MCHpg785-6
MCHCg/dL786-4
RDW%788-0
Plateletsx10E3/uL777-3
Neutrophils%770-8
Lymphs%736-9
Monocytes%5905-5
Eos%713-8
Basos%706-2
015909Neutrophils (Absolute)x10E3/uL751-8
Lymphs (Absolute)x10E3/uL731-0
015925Monocytes(Absolute)x10E3/uL742-7
Eos (Absolute)x10E3/uL711-2
Baso (Absolute)x10E3/uL704-7
Immature Granulocytes%71695-1
Immature Grans (Abs)x10E3/uL53115-2
NRBC%58413-6

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 82728, 83529, 83615

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation