Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › COVID-19 Induced Thrombotic Microangiopathy Profile

COVID-19 Induced Thrombotic Microangiopathy Profile: Labcorp test 164044

Labcorp test 164044, CPT 83615, 85240, 85246, 85379, 85397, 86162. Specimen: Serum and plasma. Turnaround: 2 - 4 days.

COVID-19 Induced Thrombotic Microangiopathy Profile is Labcorp test code 164044, billed with CPT 83615, 85240, 85246, 85379, 85397, 86162. Specimen: Serum and plasma. Turnaround time: 2 - 4 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code164044
CPT83615; 85240; 85246; 85379; 85397; 86162
LOINC14804-9, 27816-8, 3209-4, 4532-8, 48065-7, 53622-7
SpecimenSerum and plasma
Volume2 mL serum and 4.5 mL plasma (sodium citrate)
Minimum volume1 mL serum and 3 mL plasma (sodium citrate) ( Note: This volume does not allow for repeat testing.)
ContainerGel-barrier tube and blue-top (sodium citrate) tube
Turnaround time2 - 4 days
Storage / transportFrozen: Serum and plasma Room temperature: Serum

Test includes

ADAMTS13 Activity; Complement, Total (CH50); D-Dimer; Factor VIII Activity; Lactic Acid Dehydrogenase (LD); von Willebrand Profile

Use

Assessment of patients at high risk of COVID-19-associated thrombotic microangiopathy.

Methodology

See individual test components.

Collection instructions

Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge and carefully remove the plasma using a plastic transfer pipette, being careful not to disturb the cells. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze plasma within four hours of blood collection and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit seperate frozen specimens for each test requested.

Limitations

For von Willebrand Factor (vWF) Antigen [086280]: This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approvedby the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
Complement, Total (CH50)U/mL4532-8
LDHIU/L14804-9
Factor VIII Activity%3209-4
vWF Antigen%27816-8
D-Dimermg/L FEU48065-7
ADAMTS13 Activity%53622-7

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 83615, 85240, 85246

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation