Labcorp test 117310, CPT 85360, 85362, 85379, 85410, 85415, 85420. Specimen: Plasma, frozen. Turnaround: 5 - 8 days.
Use
This profile is composed of biomarkers of the fibrinolytic system.
Methodology
See individual tests.
Collection instructions
Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Double centrifugation is required for this test to ensure the removal of platelets that contain fibrinolysis factors. Centrifuge and carefully remove the plasma using a plastic transfer pipette, being careful not to disturb the cells. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Causes for rejection
Noncitrated plasma; gross hemolysis; presence of fibrin; clotted plasma
Limitations
See individual tests. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| Alpha-2-Antiplasmin | % | 27810-1 | |
| D-Dimer | mg/L FEU | 48065-7 | |
| Euglobulin Clot Lysis Time | minutes | 3244-1 | |
| FDP, Plasma | ug/mL | 30226-5 | |
| Plasminogen Act Inhibitor-1 | IU/mL | 5975-8 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 85360, 85362, 85379
- Euglobulin Clot Lysis Time (ECLT)
- Disseminated Intravascular Coagulation (DIC) Profile
- Fibrin/Fibrinogen Degradation Split Products, Plasma
- Fibrinogen Degradation Products (FDP), Plasma
- Coagulation Activation Profile
- COVID-19 Induced Thrombotic Microangiopathy Profile
- COVID-19 Poor Outcomes Risk Profile
- COVID-19 Severe Disease Progression Risk Profile
- COVID-19 Triage Profile
- D-Dimer
- D-Dimer
- D-Dimer
- DIC Panel
- Disseminated Intravascular Coagulation (DIC) Profile, Comprehensive Plus
- Prolonged Clot Time Reflexive Profile
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation