Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › FIB-4 With Reflex to Enhanced Liver Fibrosis (ELF)™

FIB-4 With Reflex to Enhanced Liver Fibrosis (ELF)™: Labcorp test 402175

Labcorp test 402175, CPT 84450, 84460, 85049. Specimen: Serum and whole blood. Turnaround: 3 - 6 days.

FIB-4 With Reflex to Enhanced Liver Fibrosis (ELF)™ is Labcorp test code 402175, billed with CPT 84450, 84460, 85049. Specimen: Serum and whole blood. Turnaround time: 3 - 6 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code402175
CPT84450; 84460; 85049
LOINC1742-6, 1920-8, 777-3
SpecimenSerum and whole blood
VolumeSerum : 2 mL divided into two tubes, 1 mL for initial testing and 1 mL for possible reflex Whole blood : tube filled to capacity
Minimum volumeSerum : 1.5 mL divided into two tubes, 0.75 mL for initial testing and 0.75 mL for possible reflex Whole blood : tube filled to capacity
ContainerGel-barrier tube or red-top tube and lavender-top (EDTA) tube
Turnaround time3 - 6 days
Storage / transportSerum sample for initial testing and whole blood can be stored at room temperature. Serum sample for possible reflex can be stored refrigerated a 2°C to 8°C for 72 hours.

Also known as: Fatty Liver Disease; Liver Fibrosis; MASH; MASLD; Metabolic Dysfunction-Associated Seatotic Liver Disease; Metabolic Dysfunction-Associated Steatohepatitis; NAFLD; NASH; Nonalcoholic Fatty Liver Disease; Noninvasive Liver Biopsy; Steatohepatitis Cirrhosis

Test includes

Alanine aminotransferase (ALT/SGPT); aspartate aminotransferase (AST/SGOT); FIB-4 Index (by calculation); platelet count. If FIB-4 Index is >1.29, testing will reflex to Enhanced Liver Fibrosis (ELF™), performed at an additional charge.

Use

According to the 2022 American Association of Clinical Endocrinology clinical practice guidelines, patients considered at high risk for Nonalcoholic Fatty Liver Disease (NAFLD), now known as metabolic dysfunction-associated steatotic liver disease (MASLD), should be screened for NAFLD and advanced fibrosis using the following blood-based tests: • To assess the risk of NAFLD with liver fibrosis, use liver fibrosis prediction calculations. The preferred noninvasive initial test is the FIB-4. • Consider persons belonging to the “high risk” group who have an indeterminate or high FIB-4 score for further workup with an ELF test. The FIB-4 index is reported to be a simple, accurate, non-invasive…

Methodology

AST and ALT: kinetic Platelet Count: automated cell counter ELF Reflex if performed: The ELF™ test consists of three fully automated, two-site sandwich immunoassays using direct chemiluminometric technology. The component assays use two monoclonal mouse antibodies: The first antibody is an acridinium ester-labeled antibody. The second antibody is a biotin-labeled antibody. The solid phase contains streptavidin-coated paramagnetic particles. The ELF™ score is derived from an algorithm that combines PIIINP, TIMP-1, and HA. ELF™ is a trademark of Siemens Healthcare Diagnostics.

Collection instructions

Serum : Separate from cells within 45 minutes of collection. Whole blood : Invert EDTA tube immediately 8 to 10 times once tube is filled at the time of collection.

Stability

TemperaturePeriod
Room temperatureSerum: 1 day; Whole blood: 1 day
RefrigeratedSerum: 3 days; Whole blood: 3 days
FrozenUnstable
Freeze/thaw cyclesUnstable

Causes for rejection

Serum: Gross hemolysis; improper labeling Whole blood: Hemolysis; clotted specimen; tube not filled with minimum volume; improper labeling; transfer tubes with whole blood; specimen diluted or contaminated with IV fluid; specimen received with plasma removed; specimen collected in any anticoagulant other than EDTA

Limitations

Clumping may cause false low platelet count. Platelet satellitism around neutrophils will cause a pseudothrombocytopenia. RBC or WBC fragments including fragmented fragile leukemic cells and neutrophil pseudoplatelets may cause falsely elevated counts.

LOINC map

Result codeResult nameUnitsResult LOINC
AST (SGOT)IU/L1920-8
ALT (SGPT)IU/L1742-6
Plateletsx10E3/uL777-3

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 84450, 84460, 85049

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation