Labcorp test 385375, CPT 84450, 85049. Specimen: Serum and whole blood. Turnaround: Within 1 day.

AST and Platelets with APRI is Labcorp test code 385375, billed with CPT 84450, 85049. Specimen: Serum and whole blood. Turnaround time: Within 1 day. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code385375
CPT84450; 85049
LOINC1920-8, 777-3
SpecimenSerum and whole blood
Volume0.5 mL (serum); fill tube to capacity (whole blood)
Minimum volume0.5 mL (serum), 0.5 mL (whole blood)
ContainerGel-barrier tube or red-top tube and lavender-top (EDTA) tube
Turnaround timeWithin 1 day
Storage / transportRoom temperature

Also known as: Fatty Liver Disease; MASH; MASLD; Metabolic Dysfunction-Associated Steatohepatitis; Metabolic Dysfunction-Associated Steatotic Liver Disease; NAFLD; Nonalcoholic Fatty Liver Disease; Noninvasive Liver Biopsy; Steatohepatitis

Use

AST to Platelet Ratio Index (APRI) is reported to be a simple, noninvasive and readily available laboratory test index that can stratify patients with HCV and nonalcoholic steatohepatitis (NASH), now known as metabolic dysfunction-associated steatohepatitis (MASH), who are at high or low risk for significant fibrosis and cirrhosis with high degree of accuracy.

Methodology

AST: kinetic; Platelet Count: automated cell counter

Collection instructions

Separate serum from cells within 45 minutes of collection; invert EDTA tube immediately 8 to 10 times once tube is filled at the time of collection.

Stability

TemperaturePeriod
Room temperature1 day
Refrigerated3 days
FrozenUnstable
Freeze/thaw cyclesUnstable

Causes for rejection

Serum: gross hemolysis; improper labeling Whole blood: hemolysis; clotted specimen; tube not filled with minimum volume; improper labeling; transfer tubes with whole blood; specimen diluted or contaminated with IV fluid; specimen received with plasma removed; specimen collected in any anticoagulant other than EDTA

Limitations

Clumping may cause false low platelet count. Platelet satellitism around neutrophils will cause a pseudothrombocytopenia. RBC or WBC fragments including fragmented fragile leukemic cells and neutrophil pseudoplatelets may cause falsely elevated counts.

LOINC map

Result codeResult nameUnitsResult LOINC
AST (SGOT)IU/L1920-8
Plateletsx10E3/uL777-3

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 84450, 85049

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation