Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Coagulation Activation Profile

Coagulation Activation Profile: Labcorp test 117410

Labcorp test 117410, CPT 83520, 85379. Specimen: Plasma, frozen. Turnaround: 5 - 8 days.

Coagulation Activation Profile is Labcorp test code 117410, billed with CPT 83520, 85379. Specimen: Plasma, frozen. Turnaround time: 5 - 8 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories, Quest Diagnostics.
LaboratoryLabcorp
CLIA number34D0655059
Test code117410
CPT83520(x2); 85379
LOINC14182-0, 25742-8, 48065-7
SpecimenPlasma, frozen
VolumeFour 2-mL platelet-poor, frozen tubes
ContainerBlue-top (sodium citrate) tubes
Turnaround time5 - 8 days
Storage / transportFreeze.

Test includes

This test includes D-dimer quantitative (automated); prothrombin fragment 1+2 MoAb; and thrombin antithrombin complex.

Use

This test is used for the measurement of levels of biomarkers associated with coagulation.

Methodology

See individual tests.

Collection instructions

Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge and carefully remove the plasma using a plastic transfer pipette, being careful not to disturb the cells. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested .

Causes for rejection

Noncitrated plasma; gross hemolysis; presence of fibrin; clotted plasma

Limitations

Levels of coagulation activation markers are increased with pregnancy with estrogen-containing birth control pills.

LOINC map

Result codeResult nameUnitsResult LOINC
D-Dimermg/L FEU48065-7
Prothrombin Fragment 1+2pmol/L25742-8
Thrombin-Antithrombin Complexng/dL14182-0

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 83520, 85379

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation