Labcorp test 115402, CPT 85362. Specimen: Plasma, frozen. Turnaround: 2 - 3 days.
Also known as: FDP, Plasma
Use
This assay is used to detect and semi quantitatively measure the presence of FDP in plasma. Fibrinolysis is the enzymatic breakdown of fibrin in blood clots. Plasmin cuts the fibrin mesh at various places, leading to the production of circulating fragments that are cleared by other proteases. Primary fibrinolysis is a normal body process. The fibrinolytic system serves to limit the formation of thrombi and to facilitate healing or recanalization of a vessel with a thrombotic occlusion. Secondary fibrinolysis is the breakdown of clots due to medicine, disorder, or other cause. Under normal conditions, the fibrinolytic process is localized on the fibrin clots because alpha 2 -antiplasmin and…
Methodology
The FDP Plasma kit provides reagents for the detection and semi-quantitation of fibrin/fibrinogen degradation products (FDP) in plasma by the use of latex particles coated with monoclonal antibodies to FDP. When FDPs are present, macroscopic agglutination occurs. Plasma FDP levels may be semi-quantitated by using dilutions of the patients plasma and comparing the agglutination pattern to a positive control.
Collection instructions
Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternative anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Double centrifugation is required for this test to ensure the removal of platelets that contain fibrinolysis factors. Centrifuge for 10 minutes and carefully remove 2/3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap, and re-centrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested . Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Reference range
<5 μg/mL
Special instructions
If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 115402 | FDP, Plasma | ug/mL | 30226-5 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 85362
- Disseminated Intravascular Coagulation (DIC) Profile
- Fibrin/Fibrinogen Degradation Split Products, Plasma
- Fibrinolysis Profile
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation