Heart Disease and Stroke Risk Profile: Labcorp test 500140
Labcorp test 500140, CPT 83695, 85246, 85384, 86141. Specimen: Serum and plasma, frozen. Turnaround: 2 - 5 days.
Test includes
C-reactive protein, cardiac; fibrinogen activity; lipoprotein (a); von Willebrand factor antigen
Methodology
See individual tests.
Collection instructions
Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples, except when using a winged blood collection device (ie, "butterfly"), in which case a discard tube should be used. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove / 3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap, and recentrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Patient preparation
Do not draw from an arm with a heparin lock or heparinized catheter.
Special instructions
State patient's sex on the request form. If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions.
Limitations
This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| Lipoprotein (a) | nmol/L | 43583-4 | |
| C-Reactive Protein, Cardiac | mg/L | 30522-7 | |
| Fibrinogen Activity | mg/dL | 3255-7 | |
| vWF Antigen | % | 27816-8 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 83695, 85246, 85384
- Lipoprotein (a)
- Lipoprotein (a) (Test on Delay as of 8/25/2026)
- Lipoprotein (a), Molarity
- Lipoprotein(a)
- Bleeding With Normal aPTT/PT
- COVID-19 Induced Thrombotic Microangiopathy Profile
- DDAVP (Desmopressin) Challenge Profile
- Menorrhagia Profile
- Post DDAVP Monitoring
- Pre DDAVP Monitoring
- Prolonged Clot Time Reflexive Profile
- von Willebrand Diagnostic Interpretive Panel (Limited)
- von Willebrand Disease Type 2N Binding
- von Willebrand Factor (vWF) Antigen
- von Willebrand Factor (vWF) Collagen-Binding Activity (CBA)
- von Willebrand Factor (vWF) Multimers
- von Willebrand Factor Antigen
- Von Willebrand Factor Antigen
- von Willebrand Factor Disease (vWD) Profile
- von Willebrand Factor Disease (vWD) Reflex Profile
- von Willebrand Factor Multimeric Panel
- von Willebrand Factor Panel
- von Willebrand Factor Panel With Reflex to von Willebrand Multimers
- Menorrhagia Profile
- Antiphospholipid Syndrome (APS) Assessment
- Coag Core Panel
- DIC Panel
- Disseminated Intravascular Coagulation (DIC) Profile
- Disseminated Intravascular Coagulation (DIC) Profile, Comprehensive Plus
- Fibrinogen
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.