von Willebrand Factor (vWF) Collagen-Binding Activity (CBA): Labcorp test 117169
Labcorp test 117169, CPT 83520, 85246. Specimen: Plasma, frozen. Turnaround: 5 - 9 days.
Also known as: vWF Collagen Binding Activity
Test includes
This test includes vWF collagen-binding activity (VWF:CB); vWF antigen (VWF:Ag); and VWF:CB/VWF:Ag ratio.
Use
This test is used to screen for the presence of type II von Willebrand disease in plasma.
Methodology
The VWF:CB assay tests the capacity of plasma VWF to bind collagen. Human Type III collagen is used. After plasma sample incubation with the collagen, residual unbound proteins are removed by washing procedures. The bound VWF is detected with anti-VWF antibodies and an assay-specific detection system.
Collection instructions
Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set, a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternative anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Causes for rejection
Lipemia; icteric specimen; hemolysis; clotted specimen; specimen contaminated with heparin (i.e., drawn with blood gases)
Reference range
CBA activity: 50% to 150% CBA ratio: 0.6−5.0 vWF antigen: 50% to 150%
Limitations
This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration. Low VWF:CB levels will be present in individuals with quantitative defects (i.e., type 1 and type 3 VWD), as well as most individuals with qualitative defects (i.e., types 2A and 2B VWD). Since this assay will not differentially identify individuals with different types of VWD on its own and may also be normal in some forms of vWD (i.e., type 2 N VWD), it is important that other VWF assays including VWF:Ag and VWF:Ac (i.e., GPIb binding) assays also be employed when assessing individuals for suspected VWD. For a more comprehensive review…
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| vWF Antigen | % | 27816-8 | |
| Collagen Binding Activity(CBA) | % | 50377-1 | |
| vWF Collagen/Antigen | Ratio | 50378-9 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 83520, 85246
- 14-3-3 eta Protein by ELISA, Serum
- 14.3.3 eta Protein, Serum
- 14.3.3 eta, Rheumatoid Arthritis
- Adalimumab Anti-Drug Antibody
- Adalimumab Level and Anti-Drug Antibody
- ADAMTS13 Antibody
- ADAMTS13 Antibody
- ADAMTS13 Reflex Panel
- Adiponectin
- Adiponectin
- Adiponectin
- Adiponectin
- Adiponectin, Quantitative Serum/Plasma
- aHUS (complement-mediated TMA) Panel
- Allergen, Hymenoptera Venoms With Components
- Alpha Subunit
- Alpha Subunit, Free, Pituitary Glycoprotein Hormones (PGH)
- ANA, IFA, Cascade and Rheumatoid Arthritis Panel 2, with Reflexes
- ANAlyzeR™ ANA, IFA with Reflex Titer/Pattern, Systemic Autoimmune Panel 1
- Angiotensin I, Plasma
- Anti-cN-1A Ab
- Anti-Mutated Citrullinated Vimentin (MCV) Antibody, Serum
- Anti-Myelin Associated Glycoprotein (MAG) IgM
- Anti-Phosphatidylethanolamine Panel
- C1 Esterase Inhibitor, Functional
- C3 Glomerulopathy Complement Panel
- CAR Autoantibody
- Coagulation Activation Profile
- Collagen Binding Assay
- Collagen Type II Antibody
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation