Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › von Willebrand Factor (vWF) Collagen-Binding Activity (CBA)

von Willebrand Factor (vWF) Collagen-Binding Activity (CBA): Labcorp test 117169

Labcorp test 117169, CPT 83520, 85246. Specimen: Plasma, frozen. Turnaround: 5 - 9 days.

von Willebrand Factor (vWF) Collagen-Binding Activity (CBA) is Labcorp test code 117169, billed with CPT 83520, 85246. Specimen: Plasma, frozen. Turnaround time: 5 - 9 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories, Quest Diagnostics, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code117169
CPT83520; 85246
LOINC27816-8, 50377-1, 50378-9
SpecimenPlasma, frozen
Volume2.0 mL
Minimum volume1.0 mL ( Note: This volume will not allow for repeat testing.)
ContainerBlue-top (sodium citrate) tube
Turnaround time5 - 9 days
Storage / transportFreeze; four freeze/thaw cycles are acceptable. Stable refrigerated for four hours.

Also known as: vWF Collagen Binding Activity

Test includes

This test includes vWF collagen-binding activity (VWF:CB); vWF antigen (VWF:Ag); and VWF:CB/VWF:Ag ratio.

Use

This test is used to screen for the presence of type II von Willebrand disease in plasma.

Methodology

The VWF:CB assay tests the capacity of plasma VWF to bind collagen. Human Type III collagen is used. After plasma sample incubation with the collagen, residual unbound proteins are removed by washing procedures. The bound VWF is detected with anti-VWF antibodies and an assay-specific detection system.

Collection instructions

Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set, a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternative anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.

Causes for rejection

Lipemia; icteric specimen; hemolysis; clotted specimen; specimen contaminated with heparin (i.e., drawn with blood gases)

Reference range

CBA activity: 50% to 150% CBA ratio: 0.6−5.0 vWF antigen: 50% to 150%

Limitations

This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration. Low VWF:CB levels will be present in individuals with quantitative defects (i.e., type 1 and type 3 VWD), as well as most individuals with qualitative defects (i.e., types 2A and 2B VWD). Since this assay will not differentially identify individuals with different types of VWD on its own and may also be normal in some forms of vWD (i.e., type 2 N VWD), it is important that other VWF assays including VWF:Ag and VWF:Ac (i.e., GPIb binding) assays also be employed when assessing individuals for suspected VWD. For a more comprehensive review…

LOINC map

Result codeResult nameUnitsResult LOINC
vWF Antigen%27816-8
Collagen Binding Activity(CBA)%50377-1
vWF Collagen/AntigenRatio50378-9

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 83520, 85246

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation