von Willebrand Factor (vWF) Multimers: Labcorp test 117245

Labcorp test 117245, CPT 85245, 85246, 85247. Specimen: Plasma, frozen. Turnaround: 5 - 7 days.

von Willebrand Factor (vWF) Multimers is Labcorp test code 117245, billed with CPT 85245, 85246, 85247. Specimen: Plasma, frozen. Turnaround time: 5 - 7 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code117245
CPT85245; 85246; 85247
LOINC107372-5, 27816-8, 52754-9, 81643-9
SpecimenPlasma, frozen
Volume2.0 mL (1 mL in two tubes)
Minimum volume1.0 mL ( Note: This volume does not allow for repeat testing.)
ContainerBlue stopper 3.2% sodium citrate plasma evacuated tube
Turnaround time5 - 7 days
Storage / transportFreeze; four freeze/thaw cycles are acceptable. Stable refrigerated for four hours.

Test includes

This test includes von Willebrand factor activity (VWF:Ag); von Willebrand factor antigen (VWF:Ac); VWF:Ag/ VWF:Ac ratio; and von Willebrand Multimer results including percent Intermediate and High Molecular Weight Fractions.

Use

This test is used to measure the relative levels of von Willebrand low molecular weight multimers (LMWM), intermediate molecular weight multimers (IMWM) and high molecular weight multimers (HMWM) in plasma.

Methodology

The Sebia Hydragel™ assay employs an agarose gel for the separation of plasma proteins according to their molecular weight. The electrophoretic separation is carried out after sample treatment with an anionic detergent. This treatment disrupts the three-dimensional structure of the plasma VWF, allowing for the electrophoretic separation of the multimers based on their molecular weight. The system can reveal the loss or retention of HMWM and also intermediate MWM (IMWM) and thus serve as an aid in the characterization of the majority of VWD cases, for example, distinguishing samples with loss of HMWM (and potentially IMWM) (being type 2A, 2B or PT-VWD) from samples without loss of HMWM…

Collection instructions

Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set, a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternative anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.

Causes for rejection

Lipemia; icteric specimen; hemolysis; clotted specimen; specimen contaminated with heparin (i.e., drawn with blood gases)

Reference range

Molecular Weight Percent Intermediate Molecular Weight vWF 25.0–50.0 High Molecular Weight vWF 45.0–65.0

Limitations

This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
vWF Antigen%27816-8
vWF Activity%107372-5
vWF Activity/AntigenRatio81643-9
117247High MW vWF%52754-9

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 85245, 85246, 85247

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation