Test includes
This test includes LA-sensitive activated partial thromboplastin time (PTT-LA); dilute Russell viper venom time (dRVVT); dilute prothrombin time (dPT); dPT confirm ratio; and thrombin time, fibrinogen. If PTT-LA, dRVVT or thrombin time are extended, reflex testing is performed and additional charges/CPT code(s) will apply. Profile also includes anticardiolipin antibodies (ACA), IgA, IgG, IgM; B2-Glycoprotein 1 Antibodies, IgA, IgG, IgM; and antiphosphatidylserine, IgG and IgM.
Use
This test is used for qualitative detection of lupus anticoagulants (LA) in plasma and semiquantitative detection of antiphospholipid antibodies in serum.
Methodology
Clot-based assays for lupus anticoagulants and enzyme-linked immunoassays (ELISAs) for antiphospholipid antibodies
Collection instructions
Plasma: Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anti-coagulant with the blood. A discard tube is not required prior to collection of coagulation samples except when using a winged blood collection device (i.e., "butterfly"), in which case a discard tube should be used. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove 2/3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap and recentifuge for 10 minutes. Use a second plastic pipette to remove plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested . It is important to centrifuge blood samples for plasma collection immediately after collection to separate the plasma from the blood cells. If immediate centrifugation is not possible, collected blood specimens should be kept on ice and centrifuged within an hour. Serum: If a red-top tube is used, transfer separate serum to a plastic transport tube. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Stability
See individual tests.
Patient preparation
Do not draw from an arm with a heparin lock or heparinized catheter.
Causes for rejection
Gross hemolysis; clotted specimen; frozen specimen thawed in transit; improper labeling
Limitations
Important note: Results are consistent with the presence of a lupus anticoagulant. As only persistent lupus anticoagulant (LA) positivity meets laboratory diagnostic criteria for antiphospholipid syndrome, repeat testing in 12 or more weeks is recommended, ideally in the absence of anticoagulant therapy. Patients with high clinical suspicion of having APS, but without presence of criteria aPL, are suggested to have “seronegative APS” (SNAPS). These patients may be positive for so-called noncriteria antiphospholipid antibodies (aPL) or be negative for the criteria aPL through insufficient sensitivity of the assays. Inherent to the test principle of phospholipid-based coagulation assays, LAC…
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| PTT-LA | sec | 34571-0 | |
| dRVVT | sec | 6303-2 | |
| 109009 | Thrombin Time | sec | 3243-3 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 85384, 85613, 85670
- Bleeding With Normal aPTT/PT
- Coag Core Panel
- DIC Panel
- Disseminated Intravascular Coagulation (DIC) Profile
- Disseminated Intravascular Coagulation (DIC) Profile, Comprehensive Plus
- Fibrinogen
- Fibrinogen
- Fibrinogen Activity
- Fibrinogen Evaluation Profile
- Fibrinogen Panel
- Heart Disease and Stroke Risk Profile
- Hypercoagulation Diagnostic Interpretive Panel
- Prolonged Clot Time Reflexive Profile
- Prolonged Protime Profile
- Fibrinogen Activity
- Fibrinogen Activity
- Prolonged Protime Profile
- Antiphospholipid Syndrome Reflex Panel
- Dilute Russell Viper Venom Time
- Intrauterine Fetal Demise/Stillborn Follow-up Profile
- Lupus Anticoagulant Reflex Panel
- Lupus Anticoagulant With Reflex
- Prolonged Activated Partial Thromboplastin Time (aPTT)
- Thrombotic Risk Assessment
- Thrombotic Risk Reflex Panel
- Thrombotic Risk, Acquired
- Intrauterine Fetal Demise/Stillborn Follow-up Profile
- Lupus Anticoagulant With Reflex
- Prolonged Activated Partial Thromboplastin Time (aPTT)
- Abnormal Bleeding Profile
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation