Labcorp test 086284, CPT 85240, 85245, 85246. Specimen: Plasma, frozen. Turnaround: 3 - 8 days.

von Willebrand Factor Disease (vWD) Reflex Profile is Labcorp test code 086284, billed with CPT 85240, 85245, 85246. Specimen: Plasma, frozen. Turnaround time: 3 - 8 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code086284
CPT85240; 85245; 85246
LOINC107372-5, 27816-8, 3209-4, 81643-9, 90919-2
SpecimenPlasma, frozen
Volume3 mL (1 mL in three tubes)
Minimum volume2 mL ( Note: This volume does not allow for repeat testing.)
ContainerBlue stopper 3.2% sodium citrate plasma evacuated tube
Turnaround time3 - 8 days
Storage / transportFreeze.

Test includes

This test includes von Willebrand factor activity (VWF:Ag); von Willebrand factor antigen (VWF:Ac); VWF:Ac/ VWF:Ag ratio; Factor VIII (FVIII) and FVIII/VWF:Ag ratio. If 1) VWF:Ac is <30% or 2) VWF:AC is 30-50% with VWF:Ac/ VWF:Ag ratio <0.7, then von Willebrand Factor (vWF) Multimers and Collagen-binding Activity (CBA) Profile are added.

Use

This test is used to diagnose von Willebrand factor (vWF) deficiency.

Methodology

See individual tests.

Collection instructions

Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set, a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternative anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.

Stability

TemperaturePeriod
Refrigerated4 hours
Freeze/thaw cyclesStable x4

Causes for rejection

Lipemia; icteric specimen; hemolysis; clotted specimen; specimen contaminated with heparin (i.e., drawn with blood gases)

Limitations

Some reflex tests in this profile were developed and their performance characteristics determined by Labcorp. These tests have not been cleared or approved by the Food and Drug Administration. See individual test information. The VWF levels can be affected by factors such as age, menstrual cycle, contraceptive use, pregnancy and comorbid conditions. VWF levels may be elevated during inflammation, after exercise and postoperatively, potentially masking VWD. The collection of samples for diagnosis should be avoided at these times, and any diagnosis of VWD must be made on samples collected on two separate occasions. VWF is an acute-phase reactant that increases in response to a variety of…

LOINC map

Result codeResult nameUnitsResult LOINC
vWF Antigen%27816-8
vWF Activity%107372-5
vWF Activity/AntigenRatio81643-9
Factor VIII Activity%3209-4
Factor VIII/vWF AntigenRatio90919-2

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 85240, 85245, 85246

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation