von Willebrand Factor (vWF) Antigen: Labcorp test 086280
Labcorp test 086280, CPT 85246. Specimen: Plasma, frozen. Turnaround: 1 - 3 days.
Also known as: Antigenic Factor VIII; CRM Assay; vWF Antigen
Use
This test is used to diagnose von Willebrand factor (vWF) deficiency.
Methodology
This assay measures the total vWF protein level, independent of the multimer composition of the plasma. In this latex immunoagglutination assay (LIA), patient plasma is mixed with vWF antibody-coated latex particles. Aggregation of the latex particles caused by vWF from the sample is measured photo-optically.
Collection instructions
Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternative anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Stability
| Temperature | Period |
|---|---|
| Frozen | 28 days |
| Freeze/thaw cycles | Stable x3 |
Patient preparation
Avoid warfarin (Coumadin®) therapy for two weeks and heparin therapy for two days prior to the test. Do not draw from an arm with a heparin lock or heparinized catheter.
Causes for rejection
Gross hemolysis; clotted specimen; frozen specimen thawed in transit; improper labeling
Reference range
50% to 150%. Average vWF levels (both antigen and activity) tend to vary by blood type. One study found the mean vWF levels by blood type to be as follows: • Type O: 74.8% • Type A: 105.6% • Type B: 116.9% • Type AB: 123.3%
Special instructions
If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions.
Limitations
A number of transient clinical conditions can raise the vWF levels of individuals with congenital deficiency into the normal range. vWF is an acute phase reactant and levels can increase due to stress, inflammation, acute infection, physical exercise, and following surgery. Levels can also increase with estrogen administration for contraception or hormone replacement. vWF levels are increased two- to three-fold in the second and third trimesters of pregnancy. Individuals with type O blood tend to have approximately 30% lower vWF levels than those with other blood types.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 086280 | vWF Antigen | % | 27816-8 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 85246
- Bleeding With Normal aPTT/PT
- COVID-19 Induced Thrombotic Microangiopathy Profile
- DDAVP (Desmopressin) Challenge Profile
- Heart Disease and Stroke Risk Profile
- Menorrhagia Profile
- Post DDAVP Monitoring
- Pre DDAVP Monitoring
- Prolonged Clot Time Reflexive Profile
- von Willebrand Diagnostic Interpretive Panel (Limited)
- von Willebrand Disease Panel
- von Willebrand Disease Type 2N Binding
- von Willebrand Factor (vWF) Collagen-Binding Activity (CBA)
- von Willebrand Factor (vWF) Multimers
- von Willebrand Factor Antigen
- von Willebrand Factor Antigen
- Von Willebrand Factor Antigen
- von Willebrand Factor Disease (vWD) Profile
- von Willebrand Factor Disease (vWD) Reflex Profile
- von Willebrand Factor Multimeric Panel
- von Willebrand Factor Panel
- von Willebrand Factor Panel With Reflex to von Willebrand Multimers
- Menorrhagia Profile
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation