Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › von Willebrand Factor (vWF) Antigen

von Willebrand Factor (vWF) Antigen: Labcorp test 086280

Labcorp test 086280, CPT 85246. Specimen: Plasma, frozen. Turnaround: 1 - 3 days.

von Willebrand Factor (vWF) Antigen is Labcorp test code 086280, billed with CPT 85246. Specimen: Plasma, frozen. Turnaround time: 1 - 3 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code086280
CPT85246
LOINC27816-8
SpecimenPlasma, frozen
Volume1 mL
ContainerBlue-top (sodium citrate) tube
Turnaround time1 - 3 days
Storage / transportFreeze.

Also known as: Antigenic Factor VIII; CRM Assay; vWF Antigen

Use

This test is used to diagnose von Willebrand factor (vWF) deficiency.

Methodology

This assay measures the total vWF protein level, independent of the multimer composition of the plasma. In this latex immunoagglutination assay (LIA), patient plasma is mixed with vWF antibody-coated latex particles. Aggregation of the latex particles caused by vWF from the sample is measured photo-optically.

Collection instructions

Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternative anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.

Stability

TemperaturePeriod
Frozen28 days
Freeze/thaw cyclesStable x3

Patient preparation

Avoid warfarin (Coumadin®) therapy for two weeks and heparin therapy for two days prior to the test. Do not draw from an arm with a heparin lock or heparinized catheter.

Causes for rejection

Gross hemolysis; clotted specimen; frozen specimen thawed in transit; improper labeling

Reference range

50% to 150%. Average vWF levels (both antigen and activity) tend to vary by blood type. One study found the mean vWF levels by blood type to be as follows: • Type O: 74.8% • Type A: 105.6% • Type B: 116.9% • Type AB: 123.3%

Special instructions

If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions.

Limitations

A number of transient clinical conditions can raise the vWF levels of individuals with congenital deficiency into the normal range. vWF is an acute phase reactant and levels can increase due to stress, inflammation, acute infection, physical exercise, and following surgery. Levels can also increase with estrogen administration for contraception or hormone replacement. vWF levels are increased two- to three-fold in the second and third trimesters of pregnancy. Individuals with type O blood tend to have approximately 30% lower vWF levels than those with other blood types.

LOINC map

Result codeResult nameUnitsResult LOINC
086280vWF Antigen%27816-8

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 85246

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation