Labcorp test 086145, CPT 85360. Specimen: Plasma, frozen. Turnaround: 6 - 8 days.

Euglobulin Clot Lysis Time (ECLT) is Labcorp test code 086145, billed with CPT 85360. Specimen: Plasma, frozen. Turnaround time: 6 - 8 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC).
LaboratoryLabcorp
CLIA number34D0655059
Test code086145
CPT85360
LOINC3244-1
SpecimenPlasma, frozen
Volume1 mL
Minimum volume0.8 mL ( Note: This volume may not allow for repeat testing.)
ContainerBlue-top (sodium citrate) tube
Turnaround time6 - 8 days
Storage / transportFreeze.

Use

The Euglobulin Clot Lysis Time is a global nonspecific screen of the fibrinolytic system.

Methodology

The basic method of euglobulin preparation involves dilution and acidification of chilled plasma to form a precipitate, which is collected and re-dissolved in higher pH buffer containing calcium. Clotting occurs rapidly and clot lysis takes place over several hours. Results are reported as lysis time.

Collection instructions

Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples, except when using a winged blood collection device (i.e., "butterfly"), in which case a discard tube should be used. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Double centrifugation is required for this test to ensure the removal of platelets that contain fibrinolysis factors. Centrifuge for 10 minutes and carefully remove 2/3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap and recentrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.

Patient preparation

Do not draw from an arm with a heparin lock or heparinized catheter.

Causes for rejection

Severe hemolysis; improper labeling; clotted specimen; specimen diluted with IV fluids; samples thawed in transit; improper sample type; sample out of stability

Reference range

277–454 minutes

Limitations

The diagnostic potential of euglobulin lysis times is limited by the extreme variation in lysis times among healthy individuals. Both hypofibrinogenemia and factor XIII deficiency may result in a shortened lysis time. The ECLT test should not be performed if the fibrinogen level is low. The ECLT results are normal in a2 antiplasmin deficiency and in Quebec platelet disorder. Shortened ECLT results are commonly due to acquired defects with increased fibrinolysis and not due to a specific fibrinolytic defect. The ELT does not have an established role in the evaluation of acquired coagulopathies. This test was developed and its performance characteristics determined by Labcorp. It has not been…

LOINC map

Result codeResult nameUnitsResult LOINC
086146Euglobulin Clot Lysis Timeminutes3244-1

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 85360

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation