Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › ADmark® Alzheimer's Evaluation, CSF

ADmark® Alzheimer's Evaluation, CSF: Quest Diagnostics test 92433

Quest Diagnostics test 92433, CPT 82234, 84393, 84394. Specimen: 2.5 mL CSF collected in a 2.5 mL Sarstedt low-bind false bottom tube (63.614.625, Quest Diagnostics supply part # ST100).

ADmark® Alzheimer's Evaluation, CSF is Quest Diagnostics test code 92433, billed with CPT 82234, 84393, 84394. Specimen: 2.5 mL CSF collected in a 2.5 mL Sarstedt low-bind false bottom tube (63.614.625, Quest Diagnostics supply part # ST100). Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories, Labcorp, ARUP Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code92433
CPT84393, 82234, 84394
LOINC—
Specimen2.5 mL CSF collected in a 2.5 mL Sarstedt low-bind false bottom tube (63.614.625, Quest Diagnostics supply part # ST100)
Minimum volume1 mL Sarstedt low-bind false bottom tube • 0.7 mL Sarstedt low protein-binding tube
ContainerCSF tube 63.614.625 (Sarstedt)
Storage / transportRefrigerated (cold packs)

Also known as: total tau; ttau; AB 42; Alzheimer’s Disease; Alzheimer's CSF; FDA CSF test; Amyloid beta 42; ptau 181

Methodology

Electrochemiluminescence (ECLIA)

Collection instructions

Perform lumbar puncture (LP) using gravity drip collection method. Avoid the use of syringes or tubings. Perform lumbar puncture (LP) before noon. Do not use the first 2 mL of CSF for AD Biomarker measurement. Subsequently, collect 2.5 mL of CSF directly into 2.5 mL Sarstedt (63.614.625) tube, or 1.5 mL of CSF directly into 1.5 mL Sarstedt (72.703.600) tube, for AD biomarker measurements. Filling tube at least 50% full is recommended. Each sample should be visually inspected for hemolysis. Do not use CSF samples which appear reddish. Instead, collect additional clear (non-hemolytic) CSF in a new Sarstedt tube. Do not process the CSF sample before transport to the measuring site (i.e., no mixing/inverting, no tube transfers, no aliquoting, and normally no centrifugation) until measurement. It is strongly recommended that the sample be kept at 2 to 8° C or -15 to -25° C during transport and storage up to the time of measurement. Only the specimen listed is acceptable for use with this assay. Standard CSF polystyrene collection tubes are NOT acceptable as exposing CSF to polystyrene tubes may decrease Abeta42 concentrations.

Stability

TemperaturePeriod
Room temperature5 days
Refrigerated14 days
Frozen56 days

Causes for rejection

Gross hemolysis • Polystyrene and polypropylene tubes other than Sarstedt (63.614.625) 2.5 mL and (72.703.600) 1.5 mL

Alternative specimen(s)

1.5 mL CSF collected in a 1.5 mL Sarstedt low protein-binding tube (72.703.600)

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 82234, 84393, 84394

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.