AD-Detect® Phosphorylated tau217(p-tau217), Elecsys®, Plasma: Quest Diagnostics test 23890
Quest Diagnostics test 23890, CPT 84393. Specimen: 0.7 mL plasma collected in an EDTA (lavender-top) tube.
AD-Detect® Phosphorylated tau217(p-tau217), Elecsys®, Plasma is Quest Diagnostics test code 23890, billed with CPT 84393. Specimen: 0.7 mL plasma collected in an EDTA (lavender-top) tube. Performing laboratory: Quest Diagnostics, CLIA
49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Labcorp, ARUP Laboratories.
Test code23890
CPT84393
LOINC—
Specimen0.7 mL plasma collected in an EDTA (lavender-top) tube
Minimum volume0.5 mL
ContainerTransport tube
Storage / transportRefrigerated (cold packs)
Also known as: 217; pT217; Phosphorylated Tau 217 (217P); Tau protein; Alzheimer; Ptau217; Phosphorylated tau217; p-tau217; plasma pTau species 217; Dementia
Methodology
Electrochemiluminescence Immunoassay
Collection instructions
Draw blood in an EDTA (lavender-top) tube. Invert to mix with preservatives. Centrifuge and transfer plasma to a labeled plastic transport tube.
Stability
| Temperature | Period |
|---|
| Room temperature | 48 hours |
| Refrigerated | 7 days |
| Frozen | 28 days |
Patient preparation
Dietary supplements containing biotin may interfere in assays and may skew results to be either falsely high or falsely low. For patients receiving the recommended daily doses of biotin, draw samples at least 8 hours following the last biotin supplementation. For patients on mega-doses of biotin supplements, draw samples at least 72 hours following the last biotin supplementation.
Causes for rejection
Gross hemolysis • Heat-inactivated samples • Samples stabilized with azide
Reference range
See Laboratory Report
View this test on Quest Diagnostics's website → · Last checked 2026-11-29
Other tests billed with CPT 84393
- AD-Detect® ABeta 42/40, p-tau217, and ApoE Evaluation, Plasma
Quest DiagnosticsTest code 16493CPT 82233, 82234, 82542, 843934 mL total frozen plasma collected in K2 EDTA (lavender-top) tubes, split into 3
- AD-Detect™ ABeta 42/40 and p-tau217 Evaluation, Plasma
Quest DiagnosticsTest code 14258CPT 82233, 82234, 843932.5 mL total plasma collected in a K2 EDTA (lavender-top) tube split into two eq
- Alzheimer’s Disease Biomarker Panel, Cerebrospinal Fluid
Cleveland Clinic LaboratoriesTest code ALZCSFCPT 82234, 84393, 84394Cerebrospinal fluid (CSF)TAT 1 - 8 days
- Alzheimer's Disease Evaluation Profile, CSF
LabcorpTest code 484415CPT 82234, 84393, 84394Cerebrospinal fluid (CSF)TAT 2 - 4 days
- Alzheimer's Disease Markers, CSF
ARUP LaboratoriesTest code 3017653CPT 82234, 84393, 84394CSFTAT 1-7 days
- ATN Profile
LabcorpTest code 484400CPT 82233, 82234, 83884, 84393Plasma, frozenTAT 7 - 10 days
- Elecsys® pTau-181, Plasma
LabcorpTest code 452560CPT 84393EDTA plasmaTAT 2 - 5 days
- Elecsys® pTau-217, Plasma
LabcorpTest code 452600CPT 84393EDTA plasma
- Lumipulse® pTau-217/Beta Amyloid 42 Ratio, Plasma
LabcorpTest code 505809CPT 82234, 84393Plasma (EDTA), frozenTAT 5 - 7 days
- Phospho-Tau 217, Plasma (Test on Referral as of 11/23/26)
ARUP LaboratoriesTest code 3019017CPT 84393Plasma (EDTA)TAT 1-8 days
- Phosphorylated Tau 217 (pTau-217), Plasma
LabcorpTest code 484390CPT 84393Plasma, frozenTAT 5 - 7 days
Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code.
Submit your lab's test menu → Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation