Quest Diagnostics test 23890, CPT 84393. Specimen: 0.7 mL plasma collected in an EDTA (lavender-top) tube.

AD-Detect® Phosphorylated tau217(p-tau217), Elecsys®, Plasma is Quest Diagnostics test code 23890, billed with CPT 84393. Specimen: 0.7 mL plasma collected in an EDTA (lavender-top) tube. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Labcorp, ARUP Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code23890
CPT84393
LOINC—
Specimen0.7 mL plasma collected in an EDTA (lavender-top) tube
Minimum volume0.5 mL
ContainerTransport tube
Storage / transportRefrigerated (cold packs)

Also known as: 217; pT217; Phosphorylated Tau 217 (217P); Tau protein; Alzheimer; Ptau217; Phosphorylated tau217; p-tau217; plasma pTau species 217; Dementia

Methodology

Electrochemiluminescence Immunoassay

Collection instructions

Draw blood in an EDTA (lavender-top) tube. Invert to mix with preservatives. Centrifuge and transfer plasma to a labeled plastic transport tube.

Stability

TemperaturePeriod
Room temperature48 hours
Refrigerated7 days
Frozen28 days

Patient preparation

Dietary supplements containing biotin may interfere in assays and may skew results to be either falsely high or falsely low. For patients receiving the recommended daily doses of biotin, draw samples at least 8 hours following the last biotin supplementation. For patients on mega-doses of biotin supplements, draw samples at least 72 hours following the last biotin supplementation.

Causes for rejection

Gross hemolysis • Heat-inactivated samples • Samples stabilized with azide

Reference range

See Laboratory Report

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 84393

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation