Phosphorylated Tau 217 (pTau-217), Plasma: Labcorp test 484390

Labcorp test 484390, CPT 84393. Specimen: Plasma, frozen. Turnaround: 5 - 7 days.

Phosphorylated Tau 217 (pTau-217), Plasma is Labcorp test code 484390, billed with CPT 84393. Specimen: Plasma, frozen. Turnaround time: 5 - 7 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Quest Diagnostics, Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code484390
CPT84393
LOINC104663-0, 77202-0
SpecimenPlasma, frozen
Volume1 mL
Minimum volume0.75 mL ( Note: This volume does not allow for repeat testing.)
ContainerLavender-top (EDTA) tube
Turnaround time5 - 7 days
Storage / transportFreeze.

Also known as: 217; p-Tau217; pTau217; Tau

Use

This test is used to aid in the biological identification of Alzheimer's disease by measuring phosphorylated tau 217, which has been shown in the literature to be a surrogate of amyloid pathology. Additionally, pTau-217 can be used for monitoring patients on newly approved anti-amyloid therapy. Clinical cutoff value was established using samples from a well-established patient cohort characterized with amyloid PET data. A pTau-217 value of >0.18 is a reported surrogate marker for beta amyloid pathology and can be used to facilitate biological identification of Alzheimer's disease. pTau-217 has also been used in clinical trials to monitor patients on anti-amyloid therapy.

Methodology

Fujirebio Lumipulse chemiluminescent enzyme immunoassay (CLEIA)

Collection instructions

Draw blood in lavender-top (EDTA) tube. Invert to mix with preservatives. Centrifuge and transfer plasma to a labeled plastic transport tube and freeze.

Stability

TemperaturePeriod
Frozen-20°C: 14 days
-80°C: 2 monthsFreeze/thaw cycles

Causes for rejection

Serum specimen; improper labeling; grossly hemolyzed

Reference range

0.00–0.18 pg/mL

Limitations

This test is performed by Fujirebio Lumipulse chemiluminescent enzyme immunoassay (CLEIA). Values obtained with different methods cannot be used interchangeably. The validated limit of quantification is 0.06 pg/mL. Assay detection limit is 0.03 pg/mL. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
484391p-tau217pg/mL104663-0
484392Footnotes77202-0

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 84393

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation