AD-Detect™ ABeta 42/40 and p-tau217 Evaluation, Plasma: Quest Diagnostics test 14258
Quest Diagnostics test 14258, CPT 82233, 82234, 84393. Specimen: 2.5 mL total plasma collected in a K2 EDTA (lavender-top) tube split into two equal aliquots.
Also known as: Phosphorylated tau; ptau 217; AB 42; Dementia; Alzheimer's Diagnostic panel; Alzheimer’s Disease; Alzheimer's diagnosis; Amyloid beta 42; Phospho tau
Methodology
Immunoassay (IA) • Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS)
Collection instructions
Quest Diagnostics does not perform this test for individuals under the age of 18. Pre-test and post-test counseling is strongly recommended. Collect blood into a K2 EDTA (lavender-top) tube and mix by inversion 10 times. Centrifuge to separate plasma from cells within 1 hour of collection. Carefully transfer plasma into 2 separate polypropylene tubes or 2 separate Quest issued polypropylene pour-off/transfer tubes. Do not transfer to conical tubes. Store frozen.
Stability
| Temperature | Period |
|---|---|
| Room temperature | Unacceptable |
| Refrigerated | 72 hours |
| Frozen | 28 days |
Patient preparation
Patients should be cautioned to stop biotin consumption at least 72 hours prior to collection of a sample
Causes for rejection
Moderate or gross hemolysis • Specimen collected in a glass, polystyrene, or polycarbonate tube • K3 EDTA tube • K2 EDTA gel separator tube
Assay category
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.
View this test on Quest Diagnostics's website → · Last checked 2026-11-29
Other tests billed with CPT 82233, 82234, 84393
- AD-Detect® ABeta 42/40, p-tau217, and ApoE Evaluation, Plasma
- ATN Profile
- Beta Amyloid 42/40 Ratio, Plasma
- Alzheimer’s Disease Biomarker Panel, Cerebrospinal Fluid
- Alzheimer's Disease Evaluation Profile, CSF
- Alzheimer's Disease Markers, CSF
- Lumipulse® pTau-217/Beta Amyloid 42 Ratio, Plasma
- AD-Detect® Phosphorylated tau217(p-tau217), Elecsys®, Plasma
- Elecsys® pTau-181, Plasma
- Elecsys® pTau-217, Plasma
- Phospho-Tau 217, Plasma (Test on Referral as of 11/23/26)
- Phosphorylated Tau 217 (pTau-217), Plasma
Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation