Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › AD-Detect™ ABeta 42/40 and p-tau217 Evaluation, Plasma

AD-Detect™ ABeta 42/40 and p-tau217 Evaluation, Plasma: Quest Diagnostics test 14258

Quest Diagnostics test 14258, CPT 82233, 82234, 84393. Specimen: 2.5 mL total plasma collected in a K2 EDTA (lavender-top) tube split into two equal aliquots.

AD-Detect™ ABeta 42/40 and p-tau217 Evaluation, Plasma is Quest Diagnostics test code 14258, billed with CPT 82233, 82234, 84393. Specimen: 2.5 mL total plasma collected in a K2 EDTA (lavender-top) tube split into two equal aliquots. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Labcorp, Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code14258
CPT82233, 82234, 84393
LOINC—
Specimen2.5 mL total plasma collected in a K2 EDTA (lavender-top) tube split into two equal aliquots
Minimum volume1.2 mL
ContainerTransport tube(s)
Storage / transportFrozen

Also known as: Phosphorylated tau; ptau 217; AB 42; Dementia; Alzheimer's Diagnostic panel; Alzheimer’s Disease; Alzheimer's diagnosis; Amyloid beta 42; Phospho tau

Methodology

Immunoassay (IA) • Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS)

Collection instructions

Quest Diagnostics does not perform this test for individuals under the age of 18. Pre-test and post-test counseling is strongly recommended. Collect blood into a K2 EDTA (lavender-top) tube and mix by inversion 10 times. Centrifuge to separate plasma from cells within 1 hour of collection. Carefully transfer plasma into 2 separate polypropylene tubes or 2 separate Quest issued polypropylene pour-off/transfer tubes. Do not transfer to conical tubes. Store frozen.

Stability

TemperaturePeriod
Room temperatureUnacceptable
Refrigerated72 hours
Frozen28 days

Patient preparation

Patients should be cautioned to stop biotin consumption at least 72 hours prior to collection of a sample

Causes for rejection

Moderate or gross hemolysis • Specimen collected in a glass, polystyrene, or polycarbonate tube • K3 EDTA tube • K2 EDTA gel separator tube

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 82233, 82234, 84393

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation