ATN Profile: Labcorp test 484400

Labcorp test 484400, CPT 82233, 82234, 83884, 84393. Specimen: Plasma, frozen. Turnaround: 7 - 10 days.

ATN Profile is Labcorp test code 484400, billed with CPT 82233, 82234, 83884, 84393. Specimen: Plasma, frozen. Turnaround time: 7 - 10 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Quest Diagnostics, Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code484400
CPT82233; 82234; 83884; 84393
LOINC101281-4, 103675-5, 33200-7, 70073-2
SpecimenPlasma, frozen
Volume3 mL
Minimum volume2.5 mL ( Note : This volume does not allow for repeat testing.)
ContainerLavender-top (EDTA) tube, screw-capped frozen transport tube
Turnaround time7 - 10 days
Storage / transportPlasma samples may be stored for up to 24 hours at < -10°C (standard freezer) prior to placing in dry ice (for shipment), or samples may be stored in the refrigerator for up to 10 hours but then must be placed on dry ice for transport. All samples must be placed on dry ice for transport and must be maintained on dry ice or similar temperatures when reaching the local lab.

Also known as: Alzheimer's; Amyloid-Tau-Neurodegeneration (ATN) Profile; Beta Amyloid 42/40 Ratio, Plasma; Neurofilament Light Chain(NfL), Plasma; Phosphorylated Tau 181 (pTau-181), Plasma

Test includes

Beta Amyloid 42/40 Ratio; Phosphorylated Tau 181 (pTau-181); Neurofilament Light Chain (NfL)

Use

This profile is used to assist in determining the presence or absence of key biological changes that are consistent with Alzheimer's disease pathology.

Methodology

Sysmex chemiluminescence enzyme immunoassay (CLEIA) and Roche Diagnostics electrochemiluminescence immunoassay (ECLIA)

Collection instructions

Draw two full lavender-top (EDTA) tubes of blood. Separate plasma from blood via centrifugation (>1500g for 10 minutes) within 40 minutes after blood collection. Transfer plasma to two Labcorp polypropylene transport tubes and seal.

Stability

TemperaturePeriod
Room temperature4 hours
Refrigerated10 hours
Frozen-10°C: 24 hours; < -60°C: 100 days
Freeze/thaw cycleStable x1

Causes for rejection

Sample at room temperature; thawed sample; only one tube of plasma

Limitations

These tests were developed and their performance characteristics determined by Labcorp. They have not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
484406Beta-amyloid 42pg/mL33200-7
Beta-amyloid 40pg/mL70073-2
T -- p-tau181pg/mL103675-5
N -- NfL, Plasmapg/mL101281-4

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 82233, 82234, 83884

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation