Sound Lab Consultants › National Lab Test Directory › Labcorp › Elecsys® pTau-181, Plasma

Elecsys® pTau-181, Plasma: Labcorp test 452560

Labcorp test 452560, CPT 84393. Specimen: EDTA plasma. Turnaround: 2 - 5 days.

Elecsys® pTau-181, Plasma is Labcorp test code 452560, billed with CPT 84393. Specimen: EDTA plasma. Turnaround time: 2 - 5 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Quest Diagnostics, Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code452560
CPT84393
LOINC103675-5
SpecimenEDTA plasma
Volume1 mL
Minimum volume0.7 mL ( Note: This volume does not allow for repeat testing.)
ContainerLavender-top (EDTA) tube
Turnaround time2 - 5 days
Storage / transportRoom temperature

Use

The Elecsys® pTau-181 plasma assay result is intended to be used as an aid in the initial assessment for Alzheimer's disease and other causes of cognitive decline in adult patients ages 55 years and older presenting with signs, symptoms or complaints of cognitive decline. The result should be interpreted in conjunction with other clinical information. A negative test result is consistent with a negative amyloid positron emission tomography (PET) scan result and reduced likelihood that a patient's cognitive impairment is due to amyloid pathology. These patients should be investigated for other causes of cognitive decline. A positive test result may not be consistent with a positive amyloid…

Methodology

Roche Diagnostics Electrochemiluminescence Immunoassay (ECLIA)

Collection instructions

Draw blood in lavender-top (EDTA) tube. Invert to mix with preservatives. Centrifuge and transfer plasma to a labeled plastic transport tube.

Stability

TemperaturePeriod
Room temperature2 days (stability determined by manufacturer or literature reference)
Refrigerated7 days (stability determined by manufacturer or literature reference)
Frozen3 months (stability determined by manufacturer or literature reference)
Freeze/thaw cyclesStable x1 (stability determined by manufacturer or literature reference)

Causes for rejection

Serum specimen; improper labeling

Reference range

pTau-181 result Interpretation Negative (≤0.722pg/mL) A negative result is consistent with a negative amyloid PET scan result. These patients should be investigated for causes of cognitive decline other than amyloid pathology. Positive (>0.722 pg/mL) A positive result may not be consistent with a positive amyloid PET scan result. Patients with an initial positive result should be further investigated to determine whether amyloid pathology can be a cause of cognitive impairment.

LOINC map

Result codeResult nameUnitsResult LOINC
452561Elecsys pTau-181pg/mL103675-5

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 84393

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation