Elecsys® pTau-181, Plasma: Labcorp test 452560
Labcorp test 452560, CPT 84393. Specimen: EDTA plasma. Turnaround: 2 - 5 days.
Use
The Elecsys® pTau-181 plasma assay result is intended to be used as an aid in the initial assessment for Alzheimer's disease and other causes of cognitive decline in adult patients ages 55 years and older presenting with signs, symptoms or complaints of cognitive decline. The result should be interpreted in conjunction with other clinical information. A negative test result is consistent with a negative amyloid positron emission tomography (PET) scan result and reduced likelihood that a patient's cognitive impairment is due to amyloid pathology. These patients should be investigated for other causes of cognitive decline. A positive test result may not be consistent with a positive amyloid…
Methodology
Roche Diagnostics Electrochemiluminescence Immunoassay (ECLIA)
Collection instructions
Draw blood in lavender-top (EDTA) tube. Invert to mix with preservatives. Centrifuge and transfer plasma to a labeled plastic transport tube.
Stability
| Temperature | Period |
|---|---|
| Room temperature | 2 days (stability determined by manufacturer or literature reference) |
| Refrigerated | 7 days (stability determined by manufacturer or literature reference) |
| Frozen | 3 months (stability determined by manufacturer or literature reference) |
| Freeze/thaw cycles | Stable x1 (stability determined by manufacturer or literature reference) |
Causes for rejection
Serum specimen; improper labeling
Reference range
pTau-181 result Interpretation Negative (≤0.722pg/mL) A negative result is consistent with a negative amyloid PET scan result. These patients should be investigated for causes of cognitive decline other than amyloid pathology. Positive (>0.722 pg/mL) A positive result may not be consistent with a positive amyloid PET scan result. Patients with an initial positive result should be further investigated to determine whether amyloid pathology can be a cause of cognitive impairment.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 452561 | Elecsys pTau-181 | pg/mL | 103675-5 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 84393
- AD-Detect® ABeta 42/40, p-tau217, and ApoE Evaluation, Plasma
- AD-Detect® Phosphorylated tau217(p-tau217), Elecsys®, Plasma
- AD-Detect™ ABeta 42/40 and p-tau217 Evaluation, Plasma
- Alzheimer’s Disease Biomarker Panel, Cerebrospinal Fluid
- Alzheimer's Disease Evaluation Profile, CSF
- Alzheimer's Disease Markers, CSF
- ATN Profile
- Elecsys® pTau-217, Plasma
- Lumipulse® pTau-217/Beta Amyloid 42 Ratio, Plasma
- Phospho-Tau 217, Plasma (Test on Referral as of 11/23/26)
- Phosphorylated Tau 217 (pTau-217), Plasma
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation