Lumipulse® pTau-217/Beta Amyloid 42 Ratio, Plasma: Labcorp test 505809
Labcorp test 505809, CPT 82234, 84393. Specimen: Plasma (EDTA), frozen. Turnaround: 5 - 7 days.
Also known as: 217/42; patu217/42 ratio; ptau217/Abeta42 ratio; Lumipulse®
Use
The Lumipulse G pTau 217/β-Amyloid 1-42 Plasma Ratio is an in vitro test using human plasma (K2EDTA) that combines the results of Lumipulse G pTau 217 Plasma and Lumipulse G β-Amyloid 1-42-N Plasma assays into a ratio of pTau 217 to β-Amyloid 1-42 concentrations using the LUMIPULSE G1200 System. The Lumipulse G pTau 217/β-Amyloid 1-42 Plasma Ratio is intended to aid healthcare providers to identify patients with amyloid pathology associated with Alzheimer’s disease. The Lumipulse G pTau 217/β-Amyloid 1-42 Plasma Ratio is indicated for adult patients, aged 50 years and older, presenting at a specialized care setting with signs and symptoms of cognitive decline. A test result ≤ 0.00370 is a…
Methodology
Fujirebio Lumipulse chemiluminescent enzyme immunoassay (CLEIA)
Collection instructions
Draw full lavender-top (EDTA) tube of blood. Immediately separate plasma from blood via centrifugation (2,000 g for 10 minutes) within two hours after blood collection. Transfer plasma to Labcorp polypropylene transport tube, seal and freeze .
Stability
| Temperature | Period |
|---|---|
| Room temperature | 3 hours |
| Refrigerated | 1 day |
| Frozen | -10°C to -60°C: |
| 1 month | Freeze/thaw cycles |
Causes for rejection
Hemolysis; lipemia; heat-treated specimen; gross bacterial contamination; wrong tube type; not stored at proper temperature
Limitations
1) This device is not intended to be used as a stand-alone test. The test results must be interpreted in conjunction with other diagnostic tools and clinical information. 2) The safety and effectiveness of the device has not been established for predicting development of dementia or other neurologic conditions or for monitoring the effect of any therapeutic product. 3) A positive result is associated with the presence of amyloid plaques or neurofibrillary tangles in the brain but does not establish a diagnosis of AD as would be established by neuropathological examination. 4) Lumipulse G pTau 217/β-Amyloid 1-42 Plasma Ratio can only be used with the Lumipulse G pTau 217 Plasma and Lumipulse…
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| pTau-217 | pg/mL | 104663-0 | |
| Beta-amyloid 42 | pg/mL | 33200-7 | |
| pTau-217/Beta Amyloid 42 Ratio | 505808 | Interpretation | 56850-1 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 82234, 84393
- AD-Detect® ABeta 42/40, p-tau217, and ApoE Evaluation, Plasma
- AD-Detect™ ABeta 42/40 and p-tau217 Evaluation, Plasma
- Alzheimer’s Disease Biomarker Panel, Cerebrospinal Fluid
- Alzheimer's Disease Evaluation Profile, CSF
- Alzheimer's Disease Markers, CSF
- ATN Profile
- Beta Amyloid 42/40 Ratio, Plasma
- AD-Detect® Phosphorylated tau217(p-tau217), Elecsys®, Plasma
- Elecsys® pTau-181, Plasma
- Elecsys® pTau-217, Plasma
- Phospho-Tau 217, Plasma (Test on Referral as of 11/23/26)
- Phosphorylated Tau 217 (pTau-217), Plasma
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation