von Willebrand Factor Multimer Analysis, Plasma: Michigan Medicine Laboratories (MLabs) test VWFMS
Michigan Medicine Laboratories (MLabs) test VWFMS, CPT 85247. Specimen: 1 ml citrated platelet-poor plasma. Turnaround: 7 - 21 days.
Also known as: Factor to sDS Gel Polymers; sDS Gel Electrophoresis; von Willebrand Factor Polymers
Use
Useful for detecting variant forms of von Willebrand disease and confirmation of diagnosis.
Collection instructions
Collect specimen in blue top (citrate) tube. Centrifuge specimen and aliquot citrate platelet-poor plasma into a plastic tube. Centrifuge plasma again and aliquot platelet-poor plasma into 2 plastic vials (no glass); vials should contain a minimum of 0.5 ml each. Freeze plasma immediately at <40 degrees C. Transport frozen specimen on dry ice. Specimen should be collected prior to coagulation factor replacement therapy. Proper collection and handling of specimens is critical; see Coagulation tab of the handbook to ensure that the proper technique is used. Please provide Factor VIII Assay, von Willebrand Factor Activity (Ristocetin Co-Factor), and von Willebrand Factor Antigen (Factor VIII Related Antigen) results from the same specimen collection if available.
Reference range
Interpretive report provided.
Limitations
Double-centrifuged specimens are critical for accurate results as platelet contamination may cause spurious results. The multimeric analysis for vWD cannot separate normal from type I vWD. A negative result does not rule out vWD, but a positive one is diagnostic of type II vWD and variants.
Section
Sendout Testing
Performed
Monday - Thursday
NY State approved
No
Performing Laboratory
Sendout Testing
View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29
Other tests billed with CPT 85247
- von Willebrand Diagnostic Interpretive Panel (Limited)
- von Willebrand Factor (vWF) Multimers
- von Willebrand Factor Multimeric Panel
- von Willebrand Factor Multimers
- von Willebrand Factor Panel With Reflex to von Willebrand Multimers
- Von Willebrand Multimer
Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.