Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Colorectal Cancer Mutation Panel (KRAS, PIK3CA, BRAF, NRAS)

Colorectal Cancer Mutation Panel (KRAS, PIK3CA, BRAF, NRAS): Quest Diagnostics test 18902

Quest Diagnostics test 18902, CPT 81210, 81275, 81276, 81309, 81311. Specimen: Formalin-fixed, paraffin-embedded tissue.

Colorectal Cancer Mutation Panel (KRAS, PIK3CA, BRAF, NRAS) is Quest Diagnostics test code 18902, billed with CPT 81210, 81275, 81276, 81309, 81311. Specimen: Formalin-fixed, paraffin-embedded tissue. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Labcorp, OHSU Laboratory Services, ARUP Laboratories, Michigan Medicine Laboratories (MLabs), Allina Health Laboratory (Abbott Northwestern).
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code18902
CPT81275, 81276, 81210, 81309, 81311 CPT coding may differ dependent on payer rules which may impact prior authorization testing. Please direct any questions regarding CPT coding to the payer being billed.
LOINC—
SpecimenFormalin-fixed, paraffin-embedded tissue
Minimum volume4 unstained charged (+) slides
ContainerFormalin-fixed, paraffin embedded tissue block
Storage / transportRoom temperature

Methodology

Next Generation Sequencing

Collection instructions

For submission of paraffin block, tissue source and block ID are required on the test requisition. A pathology report must be submitted. Shipping samples refrigerated acceptable. Shipping frozen unacceptable. Do not reject specimens. Send to Laboratory for screening.

Stability

TemperaturePeriod
Room temperature5 years
Refrigerated5 years
FrozenUnacceptable

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Alternative specimen(s)

8 unstained charged (+) slides

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 81210, 81275, 81276

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation