BRAF V600E/V600K Mutations: Michigan Medicine Laboratories (MLabs) test BRAF

Michigan Medicine Laboratories (MLabs) test BRAF, CPT 81210, 88381. Specimen: 5 mL EDTA (lavender) whole blood; 3 mL EDTA (lavender) bone marrow; Fresh/frozen tissue and fresh aspirates or body flui. Turnaround: 3 - 10 days.

BRAF V600E/V600K Mutations is Michigan Medicine Laboratories (MLabs) test code BRAF, billed with CPT 81210, 88381. Specimen: 5 mL EDTA (lavender) whole blood; 3 mL EDTA (lavender) bone marrow; Fresh/frozen tissue and fresh aspirates or body fluids; Fresh/frozen cel. Turnaround time: 3 - 10 days. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: Labcorp, ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeBRAF
CPT81210, 88381-TC (if applicable)
LOINC—
Specimen5 mL EDTA (lavender) whole blood; 3 mL EDTA (lavender) bone marrow; Fresh/frozen tissue and fresh aspirates or body fluids; Fresh/frozen cells in RPMI; Formalin-fixed, paraffin-embedded tissue; Diff-Quik stained aspirate smear. Extracted DNA is also acceptable if extracted in a CLIA certified laboratory.
Volume5 mL EDTA (lavender) whole blood; 3 mL EDTA (lavender) bone marrow; Fresh/frozen tissue and fresh aspirates or body fluids; Fresh/frozen cells in RPMI; Formalin-fixed, paraffin-embedded tissue; Diff-Quik stained aspirate smear. Extracted DNA is also acceptable if extracted in a CLIA certified laboratory.
Turnaround time3 - 10 days

Also known as: c.1798_1799GT>AA (V600K) Mutation; c.1799T>A (V600E) Mutation

Use

BRAF gene mutations occur in a variety of human malignancies including approximately 10% of colorectal cancers (CRC), 45% of papillary thyroid carcinomas (PTC), 50% of melanomas, virtually all hairy-cell leukemias (HCL), and 5-10% of gastrointestinal stromal tumors (GIST) that are negative for KIT and PDGFRA mutations. The most common BRAF mutation is the c.1799T>A (V600E) substitution. In CRC, this mutation has been associated with a limited clinical response to epidermal growth factor receptor (EGFR) targeted therapies (cetuximab or panitumumab). As a complement to KRAS mutation analysis, BRAF V600E mutation detection may predict response to these therapies. In addition, BRAF V600E…

Collection instructions

Collect blood or bone marrow in a lavender top tube. Refrigerate and send intact blood or bone marrow specimen within 48 hours of collection. Fresh tissue (preferably 0.5cm3, sent in RPMI) and fresh aspirates or body fluids are acceptable. Refrigerate and send, preferably within 24 hours. Frozen tissue specimens – preferably frozen with 1 hour of collection – may also be sent frozen on dry ice. Fresh cell suspensions in RPMI should be refrigerated and sent, preferably within 48 hours. Frozen cell suspensions – preferably frozen with 1 hour of collection – may also be sent frozen on dry ice. For formalin-fixed, paraffin-embedded tissue, a block containing an area with a high percentage of neoplastic cells (for micro-/macro-dissection) is preferred. Unstained, UNBAKED slides (5-8, 10-micron slides; 10-15 if few neoplastic cells are present) with associated H&E stained slide are also acceptable. Decalcified tissue or other fixatives will be accepted and the assay attempted, however these may result in failed testing due to degraded nucleic acid. Both blocks and slides should be stored at room temperature. A Diff-Quik stained aspirate smear (preferable containing a high percentage and overall amount of neoplastic cells) is also acceptable. Store at room temperature.

Reference range

Interpretive report provided.

Limitations

This test will only detect the c.1799T>A (V600E) and c.1798_1799GT>AA (V600K) mutations. Other rare BRAF mutations will not be detected. A negative result does not rule out the presence of BRAF V600E or V600K mutation below the sensitivity of detection (5% mutant allele).

Section

Molecular Diagnostics

Performed

Monday - Thursday

NY State approved

No

Performing Laboratory

Molecular Diagnostics

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 81210, 88381

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation