Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › BRAF Gene Mutation Analysis - Melanoma

BRAF Gene Mutation Analysis - Melanoma: Labcorp test 481110

Labcorp test 481110, CPT 81210, 88381. Specimen: Formalin-fixed, paraffin-embedded (FFPE) tissue block or slides. Turnaround: 7 - 10 days.

BRAF Gene Mutation Analysis - Melanoma is Labcorp test code 481110, billed with CPT 81210, 88381. Specimen: Formalin-fixed, paraffin-embedded (FFPE) tissue block or slides. Turnaround time: 7 - 10 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code481110
CPT81210; 88381
LOINC—
SpecimenFormalin-fixed, paraffin-embedded (FFPE) tissue block or slides
VolumeFormalin-fixed, paraffin-embedded tissue block or eight unstained slides and one matching H&E-stained slide at 5 μM.
Minimum volumeFour unstained slides at 5 μM and one matching H&E-stained slide. The minimum total tumor surface area needed for this assay is 40 mm² for 5-μm sections and >80% tumor cells.
ContainerFormalin-fixed, paraffin-embedded (FFPE) tissue blocks or slides
Turnaround time7 - 10 days
Storage / transportShip at room temperature. Store FFPE block or slides at room temperature.

Use

The THxID™-BRAF kit is an In Vitro Diagnostic device intended for the qualitative detection of the BRAFV600E and V600K mutations in DNA samples extracted from formalin-fixed paraffin-embedded (FFPE) human melanomatissue. The THxID™-BRAF kit is a real-time PCR test on the ABI 7500 Fast Dx system and is intended to be used as an aid in selecting melanoma patients whose tumors carry the BRAF V600E mutation for treatment with dabrafenib (Tafinlar®) and as an aid in selecting melanoma patients whose tumors carry the BRAF V600E or V600K mutation for treatment with trametinib (Mekinist™).

Methodology

Amplification refraction mutation-specific system (ARMS) polymerase chain reaction (PCR)

Causes for rejection

Tumor block containing insufficient tumor tissue; tumor is not melanoma primary; broken or stained slides

Special instructions

Please provide a copy of the pathology report. Direct any questions regarding this test to customer service at 800-345-4363. BRAF testing will be delayed if the pathology report is not received.

Limitations

This assay is able to detect 5% mutation in a background of wild-type DNA.

Disease

Melanoma

Technology

Molecular

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 81210, 88381

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation