Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › BRAF V600 Mutation Analysis, PCR, Cobas®

BRAF V600 Mutation Analysis, PCR, Cobas®: Quest Diagnostics test 38271

Quest Diagnostics test 38271, CPT 81210. Specimen: 1 block and 1 slide tissue collected in a paraffin-embedded tissue block accompanied by a circled H & E slide indicating.

BRAF V600 Mutation Analysis, PCR, Cobas® is Quest Diagnostics test code 38271, billed with CPT 81210. Specimen: 1 block and 1 slide tissue collected in a paraffin-embedded tissue block accompanied by a circled H & E slide indicating the area to be exam. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Labcorp, ARUP Laboratories, Michigan Medicine Laboratories (MLabs), Allina Health Laboratory (Abbott Northwestern), Cleveland Clinic Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code38271
CPT81210
LOINC—
Specimen1 block and 1 slide tissue collected in a paraffin-embedded tissue block accompanied by a circled H & E slide indicating the area to be examined or 5 slides and 1 H&E slide submit unstained slides, 5 for testing, and 1 for and H&E stain. If an H&E stained slide is sent, then only 5 USS are needed on 4 micron sections or 5 mL peripheral blood or 3 mL bone marrow collected in an EDTA (lavender-top) tube
Minimum volume1 mL whole blood • 1 mL bone marrow • 1 block and 1 slide minimum
ContainerFFPE: Sterile biohazard plastic bag Slide: Slide holder Whole blood and bone marrow: EDTA (lavender-top) tube
Storage / transportSlides: Room temperature FFPE, blood or bone marrow: Refrigerated (cold packs)

Methodology

Real-Time Qualitative Polymerase Chain Reaction

Collection instructions

Do not reject, send to lab for testing assessment. Do not centrifuge. Paraffin-embedded tissue: Room temperature or on ice pack in summer. Submit archived tissue. For tissue specimens, please provide most recent pathology report. Tissue accompanied by a circled H&E slide indicating the area to be examined. For unstained slides, 5 for testing, and 1 for an H&E stain. If an H&E stain slide is sent, then only 5 USS are needed on 4 micron sections. At least 10-20% tumor tissue required from most recent biopsy. Collect peripheral blood or bone marrow in an EDTA (lavender-top) tube.

Stability

Specimen viability decreases during transit. Send specimen to testing laboratory for viability determination. Do not freeze. Do not reject.

Causes for rejection

Decalcified tissue specimen

Reference range

Not detected

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

Assay category

This test was developed and its performance characteristics determined by med fusion. It has not been cleared or approved by the U.S. Food and Drug Administration (FDA). The FDA has determined that such clearance or approval is not necessary. This test is used for clinical purposes. It should not be regarded as investigational for research. This laboratory is certified under the Clinical Laboratory Improvement Amendments of 1988 (CLIA) as qualified to perform high complexity clinical laboratory testing. This test is not available for New York patient testing.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 81210

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation