Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › BRAF Gene Mutation Analysis

BRAF Gene Mutation Analysis: Labcorp test 570220

Labcorp test 570220, CPT 81210, 88381. Specimen: Solid tumor: formalin-fixed, paraffin-embedded (FFPE) tissue blocks or slides; thyroid fine needle aspirate (FNA). Turnaround: 5 - 7 days.

BRAF Gene Mutation Analysis is Labcorp test code 570220, billed with CPT 81210, 88381. Specimen: Solid tumor: formalin-fixed, paraffin-embedded (FFPE) tissue blocks or slides; thyroid fine needle aspirate (FNA). Turnaround time: 5 - 7 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code570220
CPT81210; 88381
LOINC18781-5, 31208-2
SpecimenSolid tumor: formalin-fixed, paraffin-embedded (FFPE) tissue blocks or slides; thyroid fine needle aspirate (FNA) Leukemia: whole blood or bone marrow
VolumeFFPE tissue block or four unstained slides and one matching H&E-stained slide at 5 μM; 5 to 10 mL FNA in CytoLyt container; 3 to 5 mL whole blood, 1 to 2 mL bone marrow
Minimum volumeTwo unstained slides and one matching H&E-stained slide at 5 μM (sample with >4mm2 and greater than or equal to 50% tumor content are preferred); 5 mL FNA; 3 mL blood, 1 mL bone marrow
ContainerFFPE tissue block or slides, lavender-top (EDTA) tube, green-top (sodium heparin) tube, yellow-top (ACD-A) tube, FNA CytoLyt container, tan-top (K2-EDTA) tube or pink-top (K2-EDTA) tube
Turnaround time5 - 7 days
Storage / transportMaintain specimen at room temperature. If specimen is to be stored prior to shipment, store at 2°C to 8°C. Store FFPE block or slides and FNA in CytoLyt container at room temperature.

Use

BRAF is an important member of the mitogen-activated protein kinase (MAPK) pathway that influences cell proliferation. This test will detect all V600 mutations of the BRAF oncogene frequently found in human cancers, such as melanoma, colorectal cancer, gastric cancer, lung cancer, ovarian cancer, thyroid cancer and hairy cell leukemia, allowing the determination of drug response, aiding the diagnosis and providing prognosis information. More than 90% of mutations are the V600E (c1799T>A) mutation, but other V600 mutations have been reported. This test can distinguish the following BRAF V600 mutations: V600E, V600E2, V600K, V600D, V600R, V600A, V600G, V600M, V600L.

Methodology

SNaPshot Multiplex PCR (primer extension-based method)

Causes for rejection

Tumor block containing no tumor; broken or stained slides; specimen does not meet collection criteria; frozen whole blood, marrow, or cell pellet; leaking tube; clotted blood or marrow; grossly hemolyzed specimen or otherwise visibly degraded; contamination by another specimen; specimens containing suspicious foreign material

Special instructions

Please provide a copy of the pathology report. Direct any questions regarding this test to customer service at 800-345-4363. BRAF testing will be delayed if the pathology report is not received.

Limitations

This assay is able to detect 5% mutation in a background of wild-type DNA. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
BRAF Mutation Analysis570222Treating Physician18781-5
BRAF Mutation Analysis570225Specimen(s) Received31208-2

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 81210, 88381

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation