BRAF Mutation Analysis: Quest Diagnostics test 16767

Quest Diagnostics test 16767, CPT 81210.

BRAF Mutation Analysis is Quest Diagnostics test code 16767, billed with CPT 81210. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Labcorp, ARUP Laboratories, Michigan Medicine Laboratories (MLabs), Allina Health Laboratory (Abbott Northwestern), Cleveland Clinic Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code16767
CPT81210
LOINC—
Minimum volume3 mL whole blood • 1 mL bone marrow aspirate • 4 unstained charged (+) slides
ContainerFormalin-fixed, paraffin-embedded tissue block
Storage / transportRoom temperature

Also known as: BRAF Mutation Analysis; B-RAF

Methodology

Next Generation Sequencing

Collection instructions

Do not reject specimens, send to laboratory for screening. For submission of paraffin block, tissue source and block ID are required on the requisition form. A pathology report must be submitted. For whole blood in EDTA specimens, sample type, collection time and date should be entered on tube and requisition form. Ship samples immediately to maintain stability. Ship samples room temperature or on ice pack in summer.

Stability

Specimen viability decreases during transit. Send specimen to testing lab for viability determination. Do not freeze. Do not reject.

Patient preparation

None Specified Preferred specimen(s) Formalin-fixed, paraffin-embedded tissue Alternative specimen(s) 5 mL whole blood or 3 mL bone marrow aspirate collected in an EDTA (lavender-top) tube or sodium heparin (green-top) tube • 8 unstained charged (+) slides

Causes for rejection

Received frozen

Reference range

Not detected

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 81210

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation