Activated Partial Thromboplastin Time: OHSU Laboratory Services test LAB00239

OHSU Laboratory Services test LAB00239, CPT 85730. Specimen: 3.2% sodium citrate tubes are acceptable provided they are filled to the line on the manufacturer's label. Tubes must be. Turnaround: Routine and Urgent: 1 Hour.

Activated Partial Thromboplastin Time is OHSU Laboratory Services test code LAB00239, billed with CPT 85730. Specimen: 3.2% sodium citrate tubes are acceptable provided they are filled to the line on the manufacturer's label. Tubes must be full (see comments . Turnaround time: Routine and Urgent: 1 Hour. Performing laboratory: OHSU Laboratory Services, CLIA 38D0676694 (Portland, OR). Other labs in the directory with tests billed under the same CPT: Labcorp, Cleveland Clinic Laboratories, Quest Diagnostics, ARUP Laboratories, Allina Health Laboratory (Abbott Northwestern).
LaboratoryOHSU Laboratory Services
CLIA number38D0676694
Test codeLAB00239
CPT85730 x 1
LOINC—
Specimen3.2% sodium citrate tubes are acceptable provided they are filled to the line on the manufacturer's label. Tubes must be full (see comments below). Whole blood specimens are stable for 4 hours at room temperature. Whole blood specimens for monitoring heparin are stable for 1 hour at room temperature or 4 hours if plasma is separated from cells. Citrate plasma separated from cells is stable for up to 14 days at -20 degrees C.
Turnaround timeRoutine and Urgent: 1 Hour

Also known as: Coags; APTT; PTT; Partial Thromboplastin Time; Activated

Reference range

Reference Range: 25.1 to 36.5 seconds Therapeutic Range: 65 to 105 seconds (Heparin concentration of 0.30 to 0.70 U/mL).

Special instructions

APTT values for monitoring heparin therapy may be affected by specimens processed greater than 1 hour after collection. Draw volume is critical due to the liquid anticoagulant. Allow tubes to fill by vacuum. Tubes with rubber stopper: fill to line on label. Tubes with plastic (Hemogard) cap: the fill level is above the top of the label. Syringe: do not remove the vacutainer stopper. Insert the needle through the stopper and allow the tube to fill by vacuum. Do not overfill the vacutainer. Pediatric tubes have no vacuum. Remove the cap and add blood to the 1.3 mL mark. Do not overfill.

Units

Seconds

Section

Core Lab

Performed

24 hours, 7 days a week.

Pediatric specimen

Add blood to the 1.3 mL mark of Pediatric BLUE top tube, 3.2% sodium citrate.

View this test on OHSU Laboratory Services's website → · Last checked 2026-11-29

Other tests billed with CPT 85730

Search the National Lab Test Directory · All OHSU Laboratory Services tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.