Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Factor VIII Inhibitor Profile, Comprehensive

Factor VIII Inhibitor Profile, Comprehensive: Labcorp test 117157

Labcorp test 117157, CPT 85240, 85730, 85732. Specimen: Plasma, frozen. Turnaround: 2 - 3 days.

Factor VIII Inhibitor Profile, Comprehensive is Labcorp test code 117157, billed with CPT 85240, 85730, 85732. Specimen: Plasma, frozen. Turnaround time: 2 - 3 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code117157
CPT85240; 85730; 85732(x3)
LOINC14979-9, 30323-0, 3209-4, 43734-3, 5946-9, 96456-9
SpecimenPlasma, frozen
Volume3 mL
ContainerBlue-top (sodium citrate) tube
Turnaround time2 - 3 days
Storage / transportFreeze

Also known as: Bethesda Titer

Test includes

Activated partial thromboplastin time (aPTT); aPTT 1:1 mix with normal plasma; aPTT 1:1 incubated mix with normal plasma; aPTT 1:1 mix with saline; factor VIII activity; factor VIII Bethesda titer

Use

Confirmation and characterization of factor VIII inhibitor

Methodology

The factor VIII inhibitor (Bethesda titer) assay is performed using an activated partial thromboplastin time (aPTT)-based test system. Serial dilutions are made of patient plasma with veronal buffered saline, then mixed with normal plasma containing close to 100% factor VIII activity and are then incubated for one hour. An aPTT-based factor VIII assay using factor VIII-depleted plasma substrate is then performed on these incubated mixtures. Results are compared to those of incubated normal plasma. One Bethesda unit is defined as the amount of factor VIII inhibitor that neutralized 0.5 IU of factor VIII in this system. The number of serial dilutions tested is based on the anticipated level…

Collection instructions

Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples, except when using a winged blood collection device (ie, "butterfly"), in which case a discard tube should be used. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove / 3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap, and recentrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.

Patient preparation

The patient should not be anticoagulated. Do not draw from an arm with a heparin lock or heparinized catheter.

Limitations

If there is residual coagulation factor activity, it could falsely lower the Bethesda titer result. Lupus anticoagulant activity and antithrombotic agents that function as inhibitors should be ruled out prior to assaying for factor inhibitors in order to avoid factitiously positive results. Some inhibitors may fully neutralize factors in less than two hours. Autoimmune inhibitors that demonstrate second order kinetics cannot always be accurately measured in the Bethesda titer system.

LOINC map

Result codeResult nameUnitsResult LOINC
117158aPTTsec14979-9
117159aPTT 1:1 Normal Plasmasec5946-9
117160aPTT 1:1 Mix Salinesec43734-3
117163aPTT 1:1 NP Mix, 60 Min,Incub.sec30323-0
086264Factor VIII Activity%3209-4

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 85240, 85730, 85732

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation