Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Allina Health Laboratory (Abbott Northwestern) › aPTT

aPTT: Allina Health Laboratory (Abbott Northwestern) test 490

Allina Health Laboratory (Abbott Northwestern) test 490, CPT 85730. Specimen: Sodium citrate (Na cit) plasma. Turnaround: 1 day.

aPTT is Allina Health Laboratory (Abbott Northwestern) test code 490, billed with CPT 85730. Specimen: Sodium citrate (Na cit) plasma. Turnaround time: 1 day. Performing laboratory: Allina Health Laboratory (Abbott Northwestern), CLIA 24D0401558 (Minneapolis, MN). Other labs in the directory with tests billed under the same CPT: Labcorp, Cleveland Clinic Laboratories, OHSU Laboratory Services, Quest Diagnostics, ARUP Laboratories.
LaboratoryAllina Health Laboratory (Abbott Northwestern)
CLIA number24D0401558
Test code490
CPT85730; Subject to medical necessity (Y/N):; Yes; LCD/NCD:; Medical necessity
LOINC—
SpecimenSodium citrate (Na cit) plasma
Volume1.5 mL
Minimum volume0.6 mL
ContainerLt blue Sodium citrate (NaCit) - 2.7mL If the patient has a hematocrit >55, a specially prepared Lt blue Sodium citrate (NaCit) tube must be used in place of the standard Lt blue Sodium citrate (NaCit) tube. Hematocrit-Anticoagulant adjustments
Turnaround time1 day

Also known as: Activated partial thromboplastin time; aPTT

Use

The activated partial thromboplastin time (aPTT) test is a screening procedure used primarily to determine deficiencies in factors necessary for the formation of intrinsic prothrombin activator, namely factors VIII, IX, XI and XII. Factors II, V and X deficiencies (normally detected by the prothrombin time) can also be detected by the aPTT. The test will not detect platelet disorders, isolated factor XII and factor XIII deficiencies.

Methodology

Clot Based Assay

Collection instructions

Do not over or under fill tube as the ratio of anticoagulant to whole blood is critical Coag – tube fill guidelines Immediatley following collection, mix sample by gentle inversion 3 - 4 times to prevent clotting

Stability

Routine: Frozen (strict) Refrigerated - NO STAT: Ambient Patient not on heparin: 4 hours Patient on heparin: specimen must be processed within 1 hour of collection, and testing run within 2 hours of collection.

Causes for rejection

Improper label (unlabeled or mislabeled) Improper anticoagulant Improperly filled tube Hemolysis Clotted specimen Delay in transport Improper storage/transport temperature Patient on heparin > 1.0 IU/mL

Reference range

0-2 months: 29 - 50 seconds 3-6 months: 28 - 43 seconds Adult: 27 - 36 seconds Heparin therapeutic range: 59 - 89 seconds Results that require action (critical): 0 - 28 days of age or outpatient: > 60 seconds

Performed

Daily Available STAT

Abbreviation

PTT

Order number

85730.0

Alternate specimens

Sodium citrate (Na cit) whole blood - STAT requests only Alternate specimen volume: 2.7 mL Alternate transport container: Lt blue Sodium citrate (NaCit) - 2.7mL

Transport container

Microcentrifuge vial/tube in a Snap cap conical vial/tube and cap (Beaker sites) Coagulation specimen transport vial/tube (all other sites)

Performing Laboratory

AHL - Coagulation: W

Processing instructions

Process Platelet Poor Plasma (P.P.P) Coag – how to prepare a specimen for special coagulation testing Transfer plasma into an aliquot tube using a spot label "NaCit Plasma P.P.P" to label as platelet poor plasma Freeze immediately

View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29

Other tests billed with CPT 85730

Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation