Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › aPTT Mixing Studies

aPTT Mixing Studies: Labcorp test 117330

Labcorp test 117330, CPT 85730. Specimen: Plasma, frozen.

aPTT Mixing Studies is Labcorp test code 117330, billed with CPT 85730. Specimen: Plasma, frozen. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code117330
CPT85730
LOINC14979-9
SpecimenPlasma, frozen
Volume2 mL
ContainerBlue-top (sodium citrate) tube
Storage / transportFreeze.

Test includes

This test includes: activated partial thromboplastin time (aPTT); reflex to aPTT 1:1 mix normal plasma (NP) of aPTT elevated more than 3.0 seconds; reflex to aPTT 1:1 mix incubated and aPTT 1:1 mix NP, incubated control if aPTT mix corrects into the normal range.

Use

This test is used to distinguish specific (i.e., factor VIII) and nonspecific (lupus anticoagulant) inhibitors; determine heparin presence and detect single or multiple factor deficiencies.

Methodology

When a mixing study is ordered, an initial aPTT test is performed to determine the extent of testing to be performed. If the initial aPTT result is within the normal range, no further testing is warranted. Also, a mixing study is only clinically informative when the aPTT result is significantly increased relative to the Upper Reference Limit (URL) (Labcorp defines significant elevation of the aPTT to be more than three seconds above the URL). This reflects the fact that both minimal factor deficiencies and weak inhibitors can be overcome by addition of NPP resulting in correction on Immediate Mix. Since a mixing study is of no value in distinguishing these distinct causes of the minimally…

Collection instructions

Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio.The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples, except when using a winged blood collection device (i.e., "butterfly"), in which case a discard tube should be used. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge and carefully remove the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.

Patient preparation

Ideally, the patient should not be on anticoagulant therapy. Avoid warfarin (Coumadin®) therapy for two weeks prior to the test and heparin, direct Xa and thrombin inhibitor therapies for about three days prior to testing. Do not draw from an arm with a heparin lock or heparinized catheter.

Causes for rejection

Severe hemolysis; improper labeling; clotted specimen; specimen diluted with IV fluids; samples thawed in transit; improper sample type; sample out of stability

Reference range

Activated Partial Thromboplastin Time (aPTT) Age Range 1d 29–38 sec 3d 25–36 sec 1 to 11 m 30–39 sec 1 to 5 y 29–37 sec 6 to 10 y 27–37 sec 11 to 16 y 25–34 sec >16 y 23–34 sec

Limitations

Mixing studies of samples with severe deficiencies of one or more factors may not correct completely due to inadequate factor levels supplied by the pooled normal plasma. Weak inhibitors can often be overcome by mixing with normal plasma, producing a correction that can be misinterpreted as factor deficiency. Mixing studies are of limited value in the assessment of patients with combined factor deficiency and inhibitor. Less significant individual factor deficiencies in combination (multiple factor deficiency) can extend the aPTT. aPTT mixing study is not definitive method for identifying the cause of an extended aPTT. Individual factor measurement and lupus anticoagulant testing may be…

LOINC map

Result codeResult nameUnitsResult LOINC
117158aPTTsec14979-9

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 85730

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation