aPTT Mixing Studies: Labcorp test 117330
Labcorp test 117330, CPT 85730. Specimen: Plasma, frozen.
Test includes
This test includes: activated partial thromboplastin time (aPTT); reflex to aPTT 1:1 mix normal plasma (NP) of aPTT elevated more than 3.0 seconds; reflex to aPTT 1:1 mix incubated and aPTT 1:1 mix NP, incubated control if aPTT mix corrects into the normal range.
Use
This test is used to distinguish specific (i.e., factor VIII) and nonspecific (lupus anticoagulant) inhibitors; determine heparin presence and detect single or multiple factor deficiencies.
Methodology
When a mixing study is ordered, an initial aPTT test is performed to determine the extent of testing to be performed. If the initial aPTT result is within the normal range, no further testing is warranted. Also, a mixing study is only clinically informative when the aPTT result is significantly increased relative to the Upper Reference Limit (URL) (Labcorp defines significant elevation of the aPTT to be more than three seconds above the URL). This reflects the fact that both minimal factor deficiencies and weak inhibitors can be overcome by addition of NPP resulting in correction on Immediate Mix. Since a mixing study is of no value in distinguishing these distinct causes of the minimally…
Collection instructions
Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio.The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples, except when using a winged blood collection device (i.e., "butterfly"), in which case a discard tube should be used. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge and carefully remove the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Patient preparation
Ideally, the patient should not be on anticoagulant therapy. Avoid warfarin (Coumadin®) therapy for two weeks prior to the test and heparin, direct Xa and thrombin inhibitor therapies for about three days prior to testing. Do not draw from an arm with a heparin lock or heparinized catheter.
Causes for rejection
Severe hemolysis; improper labeling; clotted specimen; specimen diluted with IV fluids; samples thawed in transit; improper sample type; sample out of stability
Reference range
Activated Partial Thromboplastin Time (aPTT) Age Range 1d 29–38 sec 3d 25–36 sec 1 to 11 m 30–39 sec 1 to 5 y 29–37 sec 6 to 10 y 27–37 sec 11 to 16 y 25–34 sec >16 y 23–34 sec
Limitations
Mixing studies of samples with severe deficiencies of one or more factors may not correct completely due to inadequate factor levels supplied by the pooled normal plasma. Weak inhibitors can often be overcome by mixing with normal plasma, producing a correction that can be misinterpreted as factor deficiency. Mixing studies are of limited value in the assessment of patients with combined factor deficiency and inhibitor. Less significant individual factor deficiencies in combination (multiple factor deficiency) can extend the aPTT. aPTT mixing study is not definitive method for identifying the cause of an extended aPTT. Individual factor measurement and lupus anticoagulant testing may be…
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 117158 | aPTT | sec | 14979-9 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 85730
- Abnormal Bleeding Profile
- Activated Partial Thromboplastin Time
- Antiphospholipid Syndrome Reflex Panel
- Coag Core Panel
- DIC Panel
- Dilute Thrombin Time Panel
- Disseminated Intravascular Coagulation (DIC) Profile
- Disseminated Intravascular Coagulation (DIC) Profile, Comprehensive Plus
- Elevated PT and PTT Mixing Panel
- Factor VIII Inhibitor Profile, Comprehensive
- Hypercoagulation Diagnostic Interpretive Panel
- Inhibitor Assay, PTT with Reflex to PTT 1:1 Mix, with Reflex to 1-Hour Incubation
- Lupus Anticoagulant Diagnostic Interpretive Panel
- Lupus Anticoagulant Reflex Panel
- Menorrhagia Profile
- Partial Thromboplastin Time
- Partial Thromboplastin Time (PTT), Activated
- Prolonged Clot Time Reflexive Profile
- Prothrombin Time (PT) and Partial Thromboplastin Time (PTT)
- Thrombotic Risk Reflex Panel
- von Willebrand Diagnostic Interpretive Panel (Limited)
- Menorrhagia Profile
- Partial Thromboplastin Time (PTT), Activated
- Partial Thromboplastin Time (PTT), Activated
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation